Coverage with dosimetric concordance index (CDCI): a tool for evaluating dosimetric impact of inter-observer target variability in brachytherapy

机译:带有剂量测定索引(CDCI)的覆盖:一种评估观察者间靶向近距离放射治疗的靶差异性的剂量影响的工具

获取原文
           

摘要

Purpose The aim of this study was to propose an index for evaluating dosimetric impact of inter-observer target delineation variability in brachytherapy. Material and methods The coverage with dosimetric concordance index (CDCI) is expressed as CDCIsubcommon/sub and CDCIsubpair/sub. The CDCIsubcommon/sub is the mean coverage of target volume with common volume irradiated by prescription dose among all observers and represents the condition of worst target coverage. CDCIsubpair/sub is the generalized form of CDCI, which is mean target coverage with common prescription volume obtained between all possible pairs of observers and represents more realistic coverage of target with dosimetric concordance. The index was used to evaluate the dosimetric impact of target delineation variability in optimized conformal plans on target volumes of five radiation oncologists for twenty patients of multi-catheter interstitial partial breast brachytherapy. Results The mean decline of 5.6 ±3.2% and 11.3 ±5.7% in CDCIsubpair/sub and CDCIsubcommon/sub, respectively, was observed comparing to coverage index (CI) of target volume in all patients due to inter-observer target variability. CDCIsubcommon/sub and CDCIsubpair/sub were found to have significant linear correlation (r = 0.964, p 0.000). The difference between CDC and CI increased with the mean relative target volume among observers. Significant correlation (r = 0.962, p 0.000) was also noted for the difference (Δ) in CDCIsubcommon/sub and CDCIsubpair/sub with CI of target volume. Conclusions The recommended indices and difference between the dosimetric coverage of target volume (CI) with CDCI (?CDCI) can be used for evaluating dosimetric impact of the inter-observer target delineation variability.
机译:目的本研究的目的是提出评估观察者差异目标描绘变异性在近距离放射治疗的指标的指标。材料和方法具有Dosimetric Convortance索引(CDCI)的覆盖率表示为CDCI 公共和CDCI 。 CDCI 常见的是目标体积的平均覆盖率,其在所有观察者中处方剂量辐照的常见体积,并且代表了最差目标覆盖的条件。 CDCI 是CDCI的广义形式,其平均目标覆盖具有在所有可能对观察者对之间获得的常见处方体积,并且具有更现实的目标覆盖目标,具有剂量的一致性。该指数用于评估目标描绘变异性在优化的诱导患者靶量体积中的靶标量的定义影响,为二十导管间质偏乳房放射治疗患者的靶量体积。结果CDCI 对中的平均下降5.6±3.2%和11.3±5.7%,分别分别观察到目标体积的覆盖率(CI)的覆盖率(CI),分别观察到CDCI 和Cdci 常见的所有患者因观察者间目标变异性。发现CDCI 公共和cdci 具有显着的线性相关性(r = 0.964,p <0.000)。 CDC和CI之间的差异随观察者之间的平均相对目标体积而增加。 CDCI 常见的差异(δ)还注意到具有显着的相关性(r = 0.962,p <0.000),其中CI为目标体积的CI差异(δ)中的差异(δ)。结论使用CDCI(ΔCDCI)的目标体积(CI)的推荐指标和差异可用于评估观察者间目标划分变异性的剂量效应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号