首页> 外文期刊>Journal of Diabetes Science and Technology >Fingerstick Precision and Total Error of a Point-of-Care HbA1c Test
【24h】

Fingerstick Precision and Total Error of a Point-of-Care HbA1c Test

机译:Fingersick精度和护理点HBA1C测试的总误差

获取原文
           

摘要

Background: Point-of-care (POC) HbA1c tests hold the promise of reducing the rates of undiagnosed diabetes, provided they exhibit acceptable analytical performance. The precision and total error of the POC (Afinion? HbA1c Dx) test were investigated using whole blood samples obtained by fingerstick and venipuncture. Methods: Fingerstick samples spanning the assay range were collected from 61 subjects at three representative POC sites. At each site, six fingerstick samples were obtained from each subject and tested on the POC test across two (Afinion AS100) instruments. Repeatability, between-operator, and between-instrument components of variance were calculated using analysis of variance (ANOVA). Four venous samples (low, threshold, medium, and high HbA1c) were measured in duplicate across three instruments using three reagent lots, twice per day over 20-days. Repeatability, between-run, between-day, between-lot, and between-instrument components of variance were calculated. These fingerstick and venous blood results, combined with estimates of imprecision and bias from a prior investigation, allowed for the calculation of the total coefficient of variation (CV) and total error of the POC test using fingerstick and venous whole blood samples. Results: The total imprecision ranged from 1.30% to 2.03% CV using fingerstick samples and from 1.31% to 1.64% CV using venous samples. The total error ranged from 2.87% to 4.75% using fingerstick samples and from 2.93% to 3.80% using venous samples. Conclusions: The POC test evaluated here is precise across its measuring range using both fingerstick and venous whole blood. The calculated total error of the test is well under the accepted quality requirement of ≤6%.
机译:背景:HBA1C测试能够降低未确诊糖尿病率的承诺,只要它们表现出可接受的分析性能。使用由Fingerstick和Denipuncture获得的全血样品研究了POC(AFINION?HBA1C DX)测试的精度和总误差。方法:从三个代表性PoC位点的61个受试者收集跨越测定范围的佛教谱样本。在每个网站上,从每个受试者获得六个Fingerstick样本,并在两个(Afinion AS100)仪器上测试POC测试。使用方差分析(ANOVA)计算可重复性,操作员和仪器之间的仪器组件。使用三种试剂批次,每天两次,每天两次,在三种仪器上重复测量四个静脉样品(低,阈值,培养基和高HBA1C),每天两次超过20天。计算可重复性,之间的运行之间,在白天之间,仪表之间的差异和仪器之间的仪器组件之间。这些铰接仪和静脉血液结果,与现有调查的估计相结合,允许计算总变异系数(CV)和POC测试的总误差,使用Fingersick和静脉全血样品。结果:使用Fingerstick样品的CV的总不精确度为1.30%至2.03%,使用静脉样品的1.31%至1.64%CV。使用Fingerstick样本的总误差为2.87%至4.75%,使用静脉样品的2.93%至3.80%。结论:这里评价的PoC测试在其测量范围内精确地使用Fingerstick和静脉全血。计算出的测试总误差在接受的质量要求下≤6%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号