首页> 外文期刊>Journal of Chemistry >Solid-Phase Extraction with Diethyldithiocarbamate as Chelating Agent for Preconcentration and Trace Determination of Copper, Iron and Lead in Fruit Wine and Distilled Spirit by Flame Atomic Absorption Spectrometry
【24h】

Solid-Phase Extraction with Diethyldithiocarbamate as Chelating Agent for Preconcentration and Trace Determination of Copper, Iron and Lead in Fruit Wine and Distilled Spirit by Flame Atomic Absorption Spectrometry

机译:用二乙基硫代氨基甲酸二乙基硫代氨基甲酸的固相萃取作为铜,铁和蒸煮精神中铜,铁和铅铅的螯合剂,火焰原子吸收光谱法

获取原文
           

摘要

Some heavy metals that present in wine and distilled spirit as background contamination are generally found at trace level particularly less than detection limit of common analytical techniques including flame atomic absorption spectrometry (FAAS). Thus, preconcentration method of the trace metals was developed. The optimum conditions for diethyldithiocarbamate (DDTC) complexes of Cu, Fe and Pb were then investigated for the preconcentration step using C18solid-phase extraction prior to measurement by FAAS. The preconcentration factor of 15-fold was obtained with the appropriate ratio of sample volume used (150 mL) to 10 mL final volume giving their method recoveries of Cu, Fe and Pb found in the ranges of 96.5-107, 102-116 and 91.7-107%, respectively. Precision determinations (n= 10) for 0.1 mg L-1of Cu, Fe and Pb each in a model solution were 3.7, 4.2 and 7.1 %RSD respectively. The detection limits (3SD) of Cu, Fe and Pb were found to be 1.4, 3.3 and 5.7 μg L-1, respectively. The developed method was applied to ten samples of local fruit wines and five samples of distilled spirits, resulting in the ranges of 0.012-0.80 and 0.12-8.8 mg L-1for Cu; 0.18-3.4 and 0.036-0.29 mg L-1for Fe and 0.0070-0.053 and 0.014-0.026 mg L-1for Pb, respectively. Therefore, the method is simple and inexpensive for routine analysis of the trace metals in these samples to overcome limit of detection of the instrument used.
机译:作为背景污染的葡萄酒和蒸馏精神存在的一些重金属通常在痕量水平上发现特别小于常见分析技术的检测限,包括火焰原子吸收光谱(FAAS)。因此,开发了痕量金属的预浓缩方法。然后在FAAS测量之前,使用C18Solid-相萃取研究Cu,Fe和Pb的二乙基硫代氨基甲酸酯(DDTC)复合物的最佳条件。以适当的样品体积(150mL)至10ml最终体积的样品体积的适当比例获得15倍的前浓度因子,其在96.5-107,102-116和91.7的范围内发现Cu,Fe和Pb的方法回收率分别为-107%。在模型溶液中的0.1mg,Fe和Pb的精确测定(n = 10)分别为3.7,4.2和7.1%RSD。发现Cu,Fe和Pb的检测限制(3SD)分别为1.4,3.3和5.7μgL-1。将开发的方法应用于10个当地果葡萄样品和五个蒸馏烈酒样品,导致0.012-0.80和0.12-8.8mg L-1的范围; 0.18-3.4和0.036-0.29 mg L-1FOR FE和0.0070-0.053和0.014-0.026 mg L-1 FOR PB。因此,该方法简单且廉价,用于这些样品中的痕量金属的常规分析,以克服所用仪器的检测限。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号