Purpose We compared and analyzed the detectability performance pertaining to an abdominal phantom including a region of interest (ROI) according to a computed tomography (CT) reconstruction algorithm. Methods Three types of reconstruction algorithms (FBP, SAFIRE, and ADMIRE) were used to evaluate the detectability performance using the abdominal phantom (phantom size: 25?×?18?×?28?cmsup3/sup). The vendor default settings for routine multi‐detector computed tomography abdominal scans were used. As the quantitative evaluation method, the contrast‐to‐noise ratio (CNR), difference in coefficient of variation (COV) with the normalization based on the FBP data, and the noise power spectrum (NPS) were measured. Results The characteristic of the ADMIRE‐3 reconstructed image was higher than those of the FBP and SAFIRE‐3 reconstructed images. The CNR values of the SAFIRE and ADMIRE images were much higher than the corresponding values of the FBP images. The difference in COV values for the ADMIRE images was ~1.2 times lower than the corresponding values of the SAFIRE images. Conclusion The comparative analysis of the abdominal phantom low‐contrast resolution differences for each CT exposure parameters showed that ADMIRE demonstrated better results than SAFIRE and FBP in terms of contrast, CNR, COV difference, and 1D NPS. This indicates that ADMIRE can provide a clearer observation even with the same number of contrast objects as compared to SAFIRE and FBP owing to its better contrast resolution in the central part of the contrast hole at low kV.
机译:目的是,根据计算机断层扫描(CT)重建算法,我们比较和分析了包括感兴趣区域(ROI)的腹部幻影的可检测性能。方法采用三种类型的重建算法(FBP,SAFIRE和钦佩)使用腹部幻像(幻影大小:25Ω·×18Ω×28Ω×28Ω)来评估可检测性能。使用常规多探测器计算断层扫描腹部扫描的供应商默认设置。作为定量评估方法,测量了基于FBP数据的归一化的变形率(CNR),变化系数(COV)和噪声功率谱(NPS)。结果欣赏-3重建图像的特征高于FBP和SUSIVE-3重建图像的特性。 SUSIRE和欣赏图像的CNR值远高于FBP图像的相应值。欣赏图像的COV值的差异比Safire图像的相应值低为约1.2倍。结论对每个CT曝光参数的腹部幻影低对比度分辨率差异的比较分析表明,在对比度,CNR,COV差和1D NP方面,欣赏比SAFIRE和FBP更好的结果。这表明,与在低kV处于对比度孔的中心部分中的更好的对比度分辨率,令人欣赏即使具有相同数量的对比物体,也可以提供更清晰的观察。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号