...
首页> 外文期刊>Western Journal of Emergency Medicine >Heated Ultrasound Gel and Patient Satisfaction with Bedside Ultrasound Studies: The HUGS Trial
【24h】

Heated Ultrasound Gel and Patient Satisfaction with Bedside Ultrasound Studies: The HUGS Trial

机译:加热超声凝胶与患者满意度与床头柜超声研究:拥抱试验

获取原文

摘要

Introduction: Our goal was to determine if heated gel for emergency department (ED) bedsideultrasonography improves patient satisfaction compared to room-temperature gel.Methods: We randomized a convenience sample of ED patients determined by their treating physicianto require a bedside ultrasound (US) study to either heated gel (102.0° F) or room-temperature gel(82.3° F). Investigators performed all US examinations. We informed all subjects that the study entailedinvestigation into various measures to improve patient satisfaction with ED US examinations but didnot inform them of our specific focus on gel temperature. Investigators wore heat-resistant gloves whileperforming the examinations to blind themselves to the gel temperature. After completion of the US,subjects completed a survey including the primary outcome measure of patient satisfaction as measuredon a 100-mm visual analogue scale (VAS). A secondary outcome was patient perceptions of sonographerprofessionalism measured by an ordinal scale (1-5).Results: We enrolled 124 subjects; 120 completed all outcome measures. Of these, 59 underwentrandomization to US studies with room-temperature gel and 61 underwent randomization to heated USgel. Patient 100-mm VAS satisfaction scores were 83.9 among patients undergoing studies with roomtemperaturegel versus 87.6 among subjects undergoing studies with heated gel (effect size 3.7, 95%confidence interval -1.3-8.6). There were similarly no differences between the two arms with regard topatient perceptions of sonographer professionalism.Conclusion: The use of heated ultrasound gel appears to have no material impact on the satisfaction ofED patients undergoing bedside ultrasound studies.
机译:介绍:我们的目标是确定急诊部(ED)床己针的加热凝胶是否会提高患者满意度与室温凝胶相比,提高了患者的满意度:我们随机化了由其治疗物理的ED患者的便利样品,需要床边超声(美国)研究加热凝胶(102.0°F)或室温凝胶(82.3°F)。调查人员进行了所有美国考试。我们向所有主题通报了该研究的旨在提高各种措施,以改善患者满意度与ED美国考试,但DIDNOT告诉他们我们对凝胶温度的特定重点。研究者穿着耐热手套,而检查检查以将自己盲目盲目。在完成美国之后,受试者完成了一项调查,包括患者满意度的主要结果测量,因为测量阳性为100毫米视觉模拟量表(VAS)。次要结果是患者对超级秤(1-5)的超声植物专业主义的看法。结果:我们注册了124个科目; 120完成所有结果措施。其中59例,对我们的室温凝胶和61次随机化进行了59例,对加热的USGel进行了随机化。患者100毫米VAS满意度评分为83.9患者,在接受加热凝胶研究的主题中进行了学习的研究患者,患者与87.6患者(效应大小3.7,95%置信区间-1.3-8.6)。两只武器之间的越野看起来没有差异,以缩写超声波师的专业性。结论:使用加热的超声凝胶似乎对接受床边超声研究的患者的满意度没有任何重大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号