Introduction: The prevalence of infective complications among patients undergoing Retrograde Intrarenal Surgery (RIRS) for renal stone is 1.7%-18%, including fever, Systemic Inflammatory Response Syndrome (SIRS) and sepsis. The infectious complications of RIRS can be minimised by strict aseptic precautions and plasma sterilization. The Sterrad Next Generation (Sterrad NX) System, a low-temperature sterilizer represents the next generation of low-temperature hydrogen peroxide gas plasma sterilizers. This study was conducted to evaluate the efficacy of plasma sterilization among patients undergoing ureterorenoscopy (URS) and RIRS. The primary endpoint of this study was incidence of septicemia or related complications. Till date, there is no study on the incidence of infection rate in RIRS in relation to a specific mode of sterilization. Material and Methods: This is a retrospective study comprising of 198 patients undergoing URS and/or RIRS. The parameters studied were incidence of post-operative fever, Systemic Inflammatory Response Syndrome (SIRS), pyelonephritis or septicemic shock. Results: Out of 198 patients, incidence of post-operative fever was 3.5%, SIRS was 1.7%, pyelonephritis was 0.7% and septicemic shock was 0%. This is statistically significantly low septicemia rate among patients undergoing URS and /or RIRS as compared to the available literature. No health hazards of plasma sterilization were noted. No damage to the endoscopes or instruments was noted. Conclusion: Sterrad NX based on hydrogen peroxide gas plasma (HPGP) technology is highly efficacious, safe and the modality for sterilization of instruments, including heat labile instruments such as semi rigid, flexible and chip on the tip endoscopes and other EndoUrology armamentarium.
机译:介绍:接受逆行患者患者的感染并发症的患者患者肾脏石头的患者患病率为1.7%-18%,包括发烧,全身炎症反应综合征(SIRS)和败血症。通过严格的无菌预防措施和等离子体灭菌,可以最大限度地减少RIR的传染性并发​​症。低温灭菌器的Sterrad下一代(Sterrad NX)系统表示下一代低温过氧化氢气体等离子体灭菌器。进行该研究以评估血浆灭菌患者患者患者的疗效(URS)和RIRS。本研究的主要终点是败血症或相关并发症的发病率。截至日期,没有关于RIR的发生率与特定灭菌模式的感染率发生率。材料和方法:这是一个回顾性研究,包括198名接受URS和/或RIR的患者。研究的参数是术后发烧,全身性炎症反应综合征(SIRS),肾盂肾炎或血管性休克发生率。结果:在198名患者中,术后发烧的发病率为3.5%,先生为1.7%,肾盂肾炎为0.7%,血管性休克为0%。与可用文献相比,这是统计学上显着的患者和/或RIR患者的败血症率。没有注意到血浆灭菌的健康危害。没有注意到内窥镜或仪器的损害。结论:基于过氧化氢气体等离子体(HPGP)技术的Sterrad Nx是高度有效,安全的和仪器灭菌的模型,包括热不稳定的仪器,如半刚性,柔性和芯片上的尖端内窥镜和其他宿醉的植物植物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号