This paper presents an analysis of a tunnel failure accident during shield tunnel construction on Foshan Metro Line 2 in China. The failure is caused by the leakage of the multilayer seal system, which consists of several brush seals at the tail of the shield. Four different failure modes for the multilayer seal system are discussed. A simple structural analysis of the brush seals is then conducted, and failure mode 4 (failure due to brush seal deformation) is identified as a major reason for the Foshan tunnel accident. A finite element method (FEM) analysis is employed to validate the conclusions drawn from the simple structural analysis of the brush seals.
机译:本文介绍了中国佛山地铁2号线盾构隧道施工期间的隧道故障事故分析。故障是由多层密封系统的泄漏引起的,这由屏蔽尾部的几刷密封件组成。讨论了多层密封系统的四种不同的故障模式。然后进行刷子密封件的简单结构分析,并且失效模式4(由于刷密封变形而导致的故障)被确定为佛山隧道事故的主要原因。采用有限元方法(FEM)分析来验证从刷子密封件的简单结构分析中验证的结论。