首页> 外文期刊>Quimica nova >A NEW VALIDATED METHOD FOR DETERMINATION OF ROFLUMILAST IN TABLET BY CZE-UV
【24h】

A NEW VALIDATED METHOD FOR DETERMINATION OF ROFLUMILAST IN TABLET BY CZE-UV

机译:CZE-UV测定平板电脑中罗伯鲁司司率的新验证方法

获取原文

摘要

This paper reports a new and validated capillary electrophoresis method to determine Roflumilast (RFL) with an internal standard in tablet. The separation was made on an uncoated fused-silica capillary column 50 cm effective length and 75 ?μm i.d. 20 mmol L-1 of Na2B4O7 buffer including 15% (v/v) methanol (pH=9.5) was used as background electrolyte. A potential of 20 kV was applied. The developed method was linear in the range of 0.75 ?μg mL-1 and 15.0 ?μg mL-1. LOQ and LOD values were 0.074 ?μg mL-1 and 0.022 ?μg mL-1 for inter-day, respectively. The precision value was 0.78% for inter-day. The accuracy was between 98.63 and 100.97 as recovery. This study was the first report for the determination of RFL in Daxas?? solid dosage form using CE. The validated method was found as rapid, cheap, easy to apply and uses small sample volume, very little organic solvent, and high efficiency and resolution.
机译:本文报道了一种新的和验证的毛细管电泳方法,以确定罗伯鲁克(RFL)在片剂中具有内标。将分离在未涂布的熔融二氧化硅毛细管50cm有效长度和75Ω·μm上制成。将20mmol L-1的Na 2b4O7缓冲液包括15%(v / v)甲醇(pH = 9.5)作为背景电解质。应用了20 kV的潜力。开发方法在0.75Ω×1和15.0×1和15.0Ω×1和15.0×1的线性。 LOQ和LOD值分别为日期为0.074Ω·μgmL-1和0.022ΩΩ·μgml-1。白天精度值为0.78%。恢复的准确性在98.63和100.97之间。这项研究是第一份用于在Daxas中确定RFL的报告?使用Ce的固体剂型。验证的方法被发现为快速,便宜,易于施用,并使用小样品体积,非常小的有机溶剂和高效率和分辨率。