Pillar electrical equipment is an important part of substations. The application of composite materials in pillar equipment can facilitate the improvement of the seismic performance of electrical equipment. In this paper, the test of elastic modulus and bending rigidity was conducted for individual composite elements in insulators and arresters, and the calculation formula for bending rigidity at the composite flange cementing connections was put forward. The numerical simulation model for the earthquake simulation shaking table test of ±1,100?kV composite pillar insulators was established, in which the bending rigidity value for the flange cementing part was obtained by the test or calculation formula. The numerical simulation results were compared with the earthquake simulation shaking table test results, the dynamic characteristics and seismic response of the model were compared, respectively, the validity of the proposed calculation formula for flange bending rigidity of composite cementing parts was verified, and a convenient and effective means was provided for calculating the seismic performance of composite electrical equipment.
机译:支柱电气设备是变电站的重要组成部分。复合材料在柱设备中的应用可以促进改善电气设备的地震性能。在本文中,对绝缘体和避雷器中的各个复合元件进行了弹性模量和弯曲刚度,提出了复合法兰固定连接处的弯曲刚度的计算公式。建立了±1,100 kV复合柱绝缘子的地震仿真振动台测试的数值模拟模型,其中通过试验或计算公式获得了凸缘胶粘部分的弯曲刚度值。将数值模拟结果与地震仿真摇动台测试结果进行了比较,比较了模型的动态特性和地震响应,分别进行了验证了复合粘合部件的法兰弯曲刚度的所提出的计算公式的有效性,方便提供了用于计算复合电气设备的地震性能的有效手段。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号