首页> 外文期刊>Oftal mokhirurgiya >Функциональные результаты оптимизированной асферической технологии с использованием номограммы в сравнении с асферическим и стандартным алгоритмом у пациентов с миопией на отечественной эксимерлазерной установке ?Микроскан-Визум?
【24h】

Функциональные результаты оптимизированной асферической технологии с использованием номограммы в сравнении с асферическим и стандартным алгоритмом у пациентов с миопией на отечественной эксимерлазерной установке ?Микроскан-Визум?

机译:用脊髓瘤与近视对非球面和标准算法对国内基因克瑟安装的近视和标准算法的优化非球面技术的功能结果?微生签证?

获取原文

摘要

Purpose. Comparison of FOZ (Functional-Optical Zone), Spatial-Contrast Sensitivity (SCS) under various illumination conditions, evaluation of efficacy, safety, predictability and stability in correction of myopia using the MicroScan-Visum unit in patients of comparative, control and main study groups. Material and methods. The results of FemtoLasik operations were analyzed in 78 patients with myopia (130 eyes), which were divided into the following groups: ?Nomogram? (50 eyes) – the calculation was made according to the nomogram developed by the authors; ?Aspheric? (30 eyes), where Q was 0.2; ?Standard? (50 eyes) – using the standard method. Results. In the Nomogram group, the uncorrected visual acuity (UCVA) was 1.08±0.04, the Aspheric group – 1.06±0.02, the Standard group – 1.04±0.03. In the Nomogram group, average FOZ (functional-optical zone) value was 5.71±0.09 mm, in the Aspheric group – 5.61±0.12 mm, in the Standard group – 5.38±0,75 mm. Statistically significant differences in FOZ values between the Aspheric and Nomogram groups in the area of moderate and high myopia were 5.18±0.12 mm and 5.52±0.08 mm, respectively. The visual acuity in all light conditions by 6th month was higher than the preoperative one in all the groups except the Standard group. In the SCS analysis under photopic conditions with and without light a growth of indicators in all groups at all frequencies was observed. By 6th month under mesopic conditions without light for the Aspheric and Nomogram groups a SCS recovery was noted, with difference at 18 cyclo/deg frequency, with a slight decrease for the Aspheric group, and an increase for the Nomogram group. In the mesopic conditions with light in the Aspheric and Nomogram groups, the SCS values increased on high frequencies almost twice as opposed to the preoperative level, and also the values of the Nomogram group increased twofold as opposed to those of the Aspheric group. Conclusion. The Nomogram group showed the best characteristics of efficiency, safety, predictability and stability as opposed to the comparative and control groups.
机译:目的。不同照明条件下FOZ(功能 - 光学区),空间对比度敏感度(SCS)的比较,使用微观血管单元对比较,控制和主要研究患者进行脊髓癌的疗效,安全性,可预测性和稳定性的评估团体。材料与方法。在78例近视患者(130只眼睛)中分析了Femtolasik操作的结果,分为以下组:NOMO图表? (50只眼) - 根据作者开发的墨水图进行了计算; ?非球面? (30只眼睛),其中Q为0.2; ?标准? (50只眼) - 使用标准方法。结果。在纳米图集组中,未矫正的视力(UCVA)为1.08±0.04,非球面组 - 1.06±0.02,标准组 - 1.04±0.03。在载体组中,在非球面组中,平均FOZ(功能 - 光学区)值为5.71±0.09 mm - 标准组5.61±0.12 mm - 5.38±0,75 mm。中等和高近视面积的非球面和载体组之间的FOZ值差异分别为5.18±0.12mm和5.52±0.08 mm。在除标准组之外的所有组中,所有光条件中的视力在第6个月内的视力高于术前。在具有且没有光的光学条件下的SCS分析中,观察到所有频率的所有组中的指标的生长。在没有光的缺陷条件下第六个月没有用于非球面的光和载体群,注意到SCS恢复,差异为18个环/次频率,非球面组的略有降低,并增加了墨迹组的增加。在非球面和载体组中的光的中间条件下,SCS值在高频上增加几乎与术前水平相反的两倍,并且载体组的值也与非非氟烷基团的那些增加两倍。结论。 NOMACHOM组表现出与比较和对照组相反的效率,安全性,可预测性和稳定性的最佳特征。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号