Low-cost and Efficient Fault Detection and Protection System for Distribution Transformer

机译:用于配电变压器的低成本高效故障检测和保护系统

获取原文
           

摘要

Distribution transformers are a vital component of electrical power transmission and distribution system. Frequent Monitoring transformers faults before it occurs can help prevent transformer faults which are expensive to repair and result in a loss of energy and services. The present method of the routine manual check of transformer parameters by the electricity board has proven to be less effective. This research aims to develop a low-cost protection system for the distribution transformer making it safer with improved reliability of service to the users. Therefore, this research work investigated transformer fault types and developed a microcontroller-based system for transformer fault detection and protection system using GSM (the Global System of Mobile Communication) technology for fault reporting. The developed prototype system was tested using voltage, current and temperature, which gave a threshold voltage higher than 220 volts to be overvoltage, a load higher than 200 watts to be overload and temperature greater than 39 degrees Celsius to be over temperature was measured. From the results, there was timely detection of transformer faults of the system, the transformer protection circuits were fully functional, and fault reporting was achieved using the GSM device. Overall, 99% accuracy was achieved. The system can thus be recommended for use by the Electricity Distribution Companies to protect distribution transformers for optimal performance, as the developed system makes the transformers more robust, and intelligent. Hence, a real-time distribution transformer fault monitoring and prevention system is achieved and the cost of transformer maintenance is reduced to an extent.
机译:配电变压器是电力传输和分配系统的重要组成部分。发生在发生之前的频繁监控变压器故障可能有助于防止变压器故障,这是维修的昂贵,导致能源和服务损失。通过电路板的常规手动检查的本方法已被证明是效果较低。本研究旨在为配电变压器开发低成本保护系统,使其更加安全地提高服务的可靠性。因此,该研究工作调查了变压器故障类型,并开发了一种使用GSM(全球移动通信系统)技术进行变压器故障检测和保护系统的基于微控制器的系统。使用电压,电流和温度测试开发的原型系统,该电流和温度高于220伏的过电压,测量高于200瓦的负荷,高于200瓦的温度大于39摄氏度。从结果中,有时检测系统的变压器故障,变压器保护电路是完全功能的,并且使用GSM设备实现了故障报告。总的来说,实现了99%的准确性。因此,系统可以建议使用电力配送公司用于保护分配变压器以获得最佳性能,因为开发系统使变压器更加强大,智能化。因此,实现了实时分配变压器故障监测和防止系统,并且变压器维护成本减少到程度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号