Preliminary evaluation of the VIsion PERformance (VIPER) simulator

机译:视觉性能(VIPER)模拟器的初步评估

获取原文
           

摘要

Background: This study evaluated the VIsion PERformance (VIPER) simulator’s ability to assess the functional visual performance in warfighters conducting civilian and military tasks. Methods: Thirty service members, aged 25–35 years old with a best corrected distance visual acuity (VA) better than or equal to 20/20 or logarithm of the minimum angle of resolution (logMAR) 0.00, were randomized to locate and identify road signs and mock improvised explosive devices (IEDs) under either daytime conditions or with infrared imagery, with (cc) and without (sc) wearing their habitual correction. Participants also underwent binocular uncorrected (UDVA) and corrected (CDVA) visual assessment, refraction, contrast sensitivity testing and wavefront aberrometry. Results: The mean age was 28.47 years. The manifest spherical equivalent was ? 3.16 ± 1.75 diopters (D), the UDVA in both eyes (OU) was logMAR 0.83 ± 0.47, and the CDVA OU was ? 0.11 ± 0.06. For VIPER, the mean difference in the detection distance (DD) for road signs ccDD vs. scDD was 76.7 ± 52.8 m (P 0.001). The average difference in identification distance (ID) ccID vs. scID was 13.9 ± 6.3 m (P 0.001). The mean accuracies were 83.5 and 27.9% for cc and sc, respectively (P 0.001). The regression analysis indicated that a 1.6 m change in the distance accounts for a 1% change in the accuracy (P = 0.002). Without correction, a 4.1 m change accounts for a 1% change in the accuracy (P 0.001). The average IED ccDD was 29.9 ± 8.2 m, and that for scDD was 13.2 ± 13.6 m (P 0.001). The average IED ccID was 32.2 ± 6.2 m and that for the scID was 7.4 ± 10.3 m (P 0.001). The mean IED identification accuracy was 46.7 and 11.4% for cc and sc, respectively (P 0.001). Conclusions: The preliminary results reflect VIPER’s ability to assess functional visual performance when detecting and identifying signs and IEDs. Furthermore, VIPER is able to detect performance changes with and without correction.
机译:背景:本研究评估了视觉绩效(VIPER)模拟器评估在进行民用和军事任务的战争者中的功能视觉性能的能力。方法:30岁的服务成员,25-35岁,具有最佳校正距离视力(VA)的优于或等于20/20或最小分辨率(Logmar)0.00的对数(Logmar)0.00,被随机分配以定位和识别道路在白天条件或用红外图像下,用(CC)和没有(SC)穿着其习惯性矫正的标志和模拟爆炸装置(IED)。参与者还经历了双目未校正(UDVA)和校正(CDVA)视觉评估,折射,对比度敏感性测试和波前变形性。结果:平均年龄为28.47岁。明显的球形等同物是? 3.16±1.75屈光度(d),眼睛中的UDVA(OU)是Logmar 0.83±0.47,CDVA ou是? 0.11±0.06。对于viper,道路标志的检测距离(DD)的平均差异为CCDD与SCDD为76.7±52.8 m(P <0.001)。识别距离(ID)CCID与SCID的平均差异为13.9±6.3 m(p <0.001)。 CC和SC的平均准确性分别为83.5和27.9%(P <0.001)。回归分析表明距离的1.6米的变化占精度的1%变化(P = 0.002)。在没有校正的情况下,4.1米的更改占1%的准确性变化(P <0.001)。平均IED CCDD为29.9±8.2米,SCDD为13.2±13.6米(P <0.001)。平均IED CCID为32.2±6.2米,SCID为7.4±10.3米(P <0.001)。 CC和SC的平均IED鉴定精度为46.7和11.4%(P <0.001)。结论:初步结果反映了VIPER在检测和识别迹象和IED时评估功能视觉性能的能力。此外,VIPER能够通过校正检测性能变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号