Background and study aims?Early detection of upper gastrointestinal (UGI) rebleeding is not easy by observing clinical symptoms. We developed a novel UGI monitoring system and aimed to test its feasibility of continuous tracking of UGI bleeding. Patients and methods?A prospective study was conducted on patients with moderate to high risk of rebleeding. The UGI monitoring system was installed to monitor their gastric contents. It would alarm if rebleeding was suspected and the physician could review the images to make a further decision. The patient’s comfort level was also evaluated. Results?Sixteen patients were enrolled. Rebleeding occurred in one patient and was detected by this system more than 5 hours earlier than with clinical symptoms. The interobserver reliability for reviewing the images to define the blood clearance in the stomach was excellent (intraclass correlation coefficient 0.79–0.96). The comfort level assessed by patients was 1.90?±?1.39 (on the scale of 0–5). Conclusions?This pilot study demonstrated the potential of this UGI monitoring system for early detection of rebleeding.
机译:背景和研究目的?通过观察临床症状,上胃肠道(UGI)的早期检测不容易。我们开发了一种新型的UGI监测系统,旨在测试其连续跟踪UGI出血的可行性。患者和方法?对中度至高风险的患者进行了一项前瞻性研究。安装了UGI监控系统以监测其胃内容物。如果怀疑被怀疑,医生可以审查图像以进一步决定,它会报警。还评估了患者的舒适程度。结果?16名患者注册。在一名患者中发生重燃,并通过该系统检测到比临床症状更早超过5小时。用于查看图像以定义胃中的血液间隙的interobserver可靠性是优异的(脑相关系数0.79-0.96)。患者评估的舒适程度为1.90?±1.39(在0-5的等级上)。结论?该试点研究表明,这种UGI监测系统的潜力,用于早期检测再释放。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号