...
首页> 外文期刊>American journal of men’s health. >Evaluation of Voiding Position on Uroflowmetry Parameters and Post Void Residual Urine in Patients With Benign Prostatic Hyperplasia and Healthy Men
【24h】

Evaluation of Voiding Position on Uroflowmetry Parameters and Post Void Residual Urine in Patients With Benign Prostatic Hyperplasia and Healthy Men

机译:良性前列腺增生和健康男性患者中尿液运输参数的排尿位置评价。

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Uncertainty remains whether it is best for men to void in a sitting or standing position. The objective of this study is to evaluate the effect of standing and sitting voiding position on uroflowmetry parameters and post void residual urine (PVRU) in patients with lower urinary tract symptoms (LUTS) due to benign prostate hyperplasia (BPH) and healthy men. A total of 116 participants with BPH (Group 1) and 78 healthy men (Group 2) were enrolled in the study. The uroflowmetry parameters were measured in both positions. The PVRU volume was measured using transabdominal ultrasound after each voiding. Uroflowmetry parameters and PVRU were measured and compared between the two different voiding positions using Wilcoxon signed rank test. In Group 1, there were significant statistical differences in uroflowmetry parameters between standing and sitting voiding position. The median of maximum flow rate in Group 1 in standing and sitting position was 14.7 ml/s (IQR; 11.7–17.5) and 11 ml/s (IQR; 8.9–13.3), respectively (p .0001). The median voided volume at standing position was 340 ml (IQR; 276–455) while it was 267 ml (IQR; 194–390) at sitting position (p .0001). Median average flow rate in standing position was 5.9 ml/s (IQR; 4.5–7.5) and 5 ml (IQR; 3.2–6.4) in sitting position. There was a statistically significant difference between the median of PVRU in standing and sitting position (p .0001). In patients with BPH, voiding in standing position showed better uroflowmetry parameters and significant less PVRU volume.
机译:不确定性仍然是男人在坐姿或站立位置是否最好。本研究的目的是评估站立和坐在尿液向导参数上的效果,并且由于良性前列腺增生(BPH)和健康男性而导致的尿路症状(LUT)患者的患者患者患者。共有116名与BPH(第1组)和78名健康男性(第2组)的参与者参加了该研究。在两个位置测量UROFLOWMMORRY参数。每次空隙后使用Transabdominal超声测量PVRU体积。使用Wilcoxon签名等级测试测量并比较了尿尿伞运动参数和PVRU。在第1组中,站立和坐空隙位置之间的UROFLOWMMORRY参数存在显着的统计差异。站立和坐姿1组1中最大流速的中位数分别为14.7mL / s(IQR; 11.7-17.5)和11ml / s(IQR; 8.9-13.3)(P <.0001)。站立位置处的中位数空隙量为340毫升(IQR; 276-455),坐姿为267毫升(IQR; 194-390)(P <.0001)。站立位置的中位平均流量为5.9毫升/秒(IQR; 4.5-7.5)和5毫升(IQR; 3.2-6.4)的坐姿。 PVRU中位于站立和坐姿(P <.0001)之间存在统计学上的差异。在BPH的患者中,在立体位置的空隙显示出更好的UROFLOWMMOTRY参数和显着的PVRU体积。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号