Limb Occlusion Pressure: A Method to Assess Changes in Systolic Blood Pressure

机译:肢体闭塞压力:一种评估收缩压变化的方法

获取原文

摘要

International Journal of Exercise Science 13(2): 366-373, 2020. Although often used as a surrogate, comparisons between traditional blood pressure measurements and limb occlusion assessed via hand-held Doppler have yet to be completed. Using limb occlusion pressure as a method of assessing systolic pressure is of interest to those studying the acute effects of blood flow restriction, where the removal of the cuff may alter the physiological response. Purpose: We sought to determine how changes in limb occlusion pressure track with changes in traditional assessments of blood pressure. Basic Procedures: Limb occlusion pressure measured by hand-held Doppler and blood pressure measured by an automatic blood pressure cuff were assessed at rest and following isometric knee extension (post and 5 minutes post). Main Findings: Each individual had a similar dispersion from the mean value for both the limb occlusion pressure measurement and traditional systolic blood pressure measurement [BF10: 0.33; median (95% credible interval): 0.02 (-6.0, 5.9) %]. In response to lower body isometric exercise, blood pressure changed across time. The difference between measurements was small at immediately post and 5 minutes post. The Bayes factors were in the direction of the null but did not exceed the threshold needed to accept the null hypothesis. However, at 5 minutes post, the differences were within the range of practical equivalence (within ± 4.6%). Principal Conclusions: Our findings suggest that changes in limb occlusion pressure measured by hand-held Doppler track similarly to traditional measurements of brachial systolic blood pressure following isometric knee extension exercise.
机译:国际运动科学杂志13(2):366-373,2020。虽然经常用作替代物,但通过手持多普勒评估的传统血压测量和肢体闭塞之间的比较尚未完成。利用肢体闭塞压力作为评估收缩压的方法对研究血流限制的急性效应的方法感兴趣,其中去除袖带可能会改变生理反应。目的:我们试图确定肢体遮挡压力轨道的变化如何随着传统血压评估的变化。基本程序:通过手持式多普勒测量的肢体闭塞压力和通过自动血压袖口测量的血压进行评估,并在休息和等距膝关节延伸(柱和5分钟后)。主要发现:每个单独的分散与肢体闭塞压力测量和传统的收缩压测量的平均值相似[BF10:0.33;中位数(95%可靠间隔):0.02(-6.0,5.9)%]。响应较低的身体锻炼,血压在时间变化。测量之间的差异在立即张贴和5分钟后较小。贝叶斯因子在空的方向上,但没有超过接受零假设所需的阈值。但是,在5分钟后,差异在实际等价范围内(±4.6%)。主要结论:我们的研究结果表明,通过手持多普勒轨道测量的肢体闭塞压力的变化与等距膝关节延长运动后的臂上收缩压的传统测量相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号