【24h】

Analysis of Unguyed Spar-Trees

机译:对无纹理翼梁树的分析

获取原文
           

摘要

Unguyed spar-trees are commonly used as a part of skyline cable logging systems. Finite Element Analysis is a robust method for determining spar-tree design load that can include virtually any field condition likely to be encountered. The results of Finite Element Analysis over a range of spar-trees similar in size to those typically found in second-growth Douglas-fir stands indicates that (1) some existing guidelines for use of unguyed spar-trees do not correspond to expected field behavior, and (2) lateral loads of a magnitude found in skyline cable yarding systems dominate the structural behavior of unguyed spar-trees. However, the Euler Buckling load which has been used as a guide to spar-tree capacity, may serve to normalize the results of Finite Element Analysis in such a way that simple linear relationships can be used to estimate spar-tree capacity.
机译:未核丝的翼梁树通常用作地平线电缆测井系统的一部分。有限元分析是用于确定翼梁树设计负载的鲁棒方法,这些方法几乎可以包括可能遇到的任何现场条件。有限元分析的结果在一系列类似于尺寸的翼梁树上,通常在第二次增长道格拉斯 - 冷杉站中发现的那些表明(1)一些现有的使用未经伪血清树木的指南与预期的现场行为不符(2)天际线缆造型系统中发现的幅度的(2)横向载荷占主导地位神经血管树木的结构行为。然而,已被用作翼梁树容量的引导件的欧拉屈曲负荷可以用于使有限元分析的结果正常化,以便可以使用简单的线性关系来估计翼梁树容量。