Screen printed carbon electrodes (SPCEs) provide attractive opportunity for sensitive and selective determination target analytes in clinical samples. The aim of the current work was to develop SPCEs based sensor for the determination of uric acid in clinical serum samples. The electrodes were pretreated by soaking in N,N-dimethylformamide for 5 minutes followed by drying in an oven at 100°C for 20 mins. The effect of surface pretreatment was characterized using cyclic voltammetry. The current response of uric acid detection was improved by a factor of 3.5 in differential pulse voltammetric measurement compared to unmodified electrode. Under the optimized conditions, the sensor displayed two dynamic linear ranges 5-100 μM and 100-500 μM with correlation coefficient, R2, values of 0.98782 and 0.97876, respectively. The limit of detection and limit of quantification calculated using the dynamic linear range 5-100 μM were 1.9 x 10?7 M and 6.33 x 10?7 M, respectively. The developed sensor displayed well separated and discerned peaks for UA in presence of the potential interferent (ascorbic acid and citric acid). The electrode was successfully applied for the detection of very low level of UA in clinical serum samples in a phosphate buffer solution (pH = 7). The proposed sensor showed a very high reproducibility and repeatability with the relative standard deviation of 0.9%. In conclusion, a simple and low cost sensor based on SPCEs is developed for sensitive and selective detection of uric acid in clinical samples.
机译:丝网印刷碳电极(SPCES)为临床样品中的敏感和选择性测定靶分析物提供有吸引力的机会。目前工作的目的是开发基于SPCES的传感器,用于测定临床血清样品中的尿酸。通过在N,N-二甲基甲酰胺中浸泡5分钟,然后在100℃下在烘箱中干燥20分钟的电极进行预处理。使用循环伏安法表征表面预处理的影响。与未修饰的电极相比,尿酸检测的电流响应提高了3.5的差分脉冲伏安测量。在优化条件下,传感器显示两个动态线性范围5-100μm和100-500μm,具有相关系数,R2,0.98782和0.97876的值。使用动态线性范围计算的检测极限和量化限制5-100μm为1.9×10?7 m和6.33×10?7 m。在潜在的干扰(抗坏血酸和柠檬酸)存在下,发达的传感器显示出UA的良好分离和辨别的峰。在磷酸盐缓冲溶液(pH = 7)中,成功地应用于在临床血清样品中检测非常低水平的UA。所提出的传感器显示出非常高的再现性和可重复性,相对标准偏差为0.9%。总之,基于SPCE的简单和低成本的传感器开发用于临床样品中尿酸的敏感和选择性检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号