首页> 外文期刊>Indian Journal of Pathology and Microbiology >Comparison of liquid-based cytology with conventional cytology in the evaluation of abdominal masses
【24h】

Comparison of liquid-based cytology with conventional cytology in the evaluation of abdominal masses

机译:常规细胞学在腹部群众评价中的液体基细胞学比较

获取原文
       

摘要

Context: Liquid-based cytology. Aims: Utility of liquid-based cytology (LBC) was compared to conventional smear cytology in ultrasound-guided fine-needle aspirates of abdominal masses. Settings and Design: This was a prospective comparative study conducted in collaboration with surgery and pediatrics surgery departments of our institute. Subjects and Methods: Thirty patients presenting with evidence of abdominal mass were enrolled for the study and underwent fine-needle aspiration cytology. The material was processed for the preparation of conventional smears and residual material was rinsed into cytolyt for LBC by Thin Prep method and into cell block fluid. The smears prepared from both the methods were compared by two independent and experienced pathologists for adequacy, cellularity, architectural pattern, cytoplasmic preservation, nuclear preservation, and background. Results: Cellularity was frequently higher in the conventional smears than on Thin Prep slides (P value = 0.025). Recognition of architecture was better on the conventional smears (P value = 0.001). Cytoplasm was better preserved on the conventional smears (P value = 0.001) but difference in the preservation of nuclear details was not statistically significant on slides prepared from both the techniques. The background of Thin Prep slides is significantly cleaner than direct smears (P value = 0.001). Non epithelial elements such as mucin and neurofibrillary tangles were better preserved on direct smears (P value = 0.001) but diagnostic accuracy of both the methodologies showed no statistically significant difference (P value = 0.226). Conclusions: The Thin Prep technique utilizes expensive equipment and reagents. It also generates certain morphological artefacts in slides with which a cytologist needs to get familiar. When used in isolation, it may not consistently provide any added advantage in the diagnosis of such lesions and should be used as an adjunct to conventional smears. It may be preferred in situations where material has to be transported for processing or is required for ancillary tests.
机译:背景:基于液体的细胞学。目的:将液体基细胞学(LBC)的效用与腹部超声引导的细针吸气物中的常规涂片细胞学进行比较。设置和设计:这是与我们研究所的外科和小儿科手术部门合作进行的预期比较研究。受试者和方法:患有腹部肿块证据的30名患者均注册了研究和接受细针穿刺细胞学。将材料加工成用于制备常规涂片,并通过薄的预洗涤方法并进入细胞嵌段流体将残​​留物质冲入CytoLyt中。由两种方法制备的涂片由两个独立,经验丰富的病理学家进行了比较,用于充分性,细胞性,建筑模式,细胞质保存,核保存和背景。结果:常规涂片上的细胞性频率频率低于薄的准备幻灯片(P值= 0.025)。在传统涂片上识别架构(P值= 0.001)更好。细胞质更好地保存在常规涂片上(P值= 0.001),但在由两种技术制备的载玻片上,核细节的保存的差异在统计学上没有统计学意义。薄制载的背景明显清洁,而不是直接涂抹(P值= 0.001)。诸如粘蛋白和神经原纤维缠结的非上皮元素在直接涂抹上更好地保存(P值= 0.001),但两种方法的诊断准确性显示出没有统计学上显着的差异(P值= 0.226)。结论:薄的预备技术利用昂贵的设备和试剂。它还在载玻片中产生某些形态伪影,细胞学家需要熟悉。当用于隔离时,可能不会在诊断这些病变时不断提供任何额外的优势,并且应用作常规涂片的辅助。在必须运输以进行处理或需要辅助测试的情况下,可能是优选的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号