首页> 外文期刊>Advances in urology >Histological Inflammation in Human Ureter either Healthy or Fitted with Double-Pigtail Stent or a Thin 0.3?F Suture Thread: A Preliminary Study
【24h】

Histological Inflammation in Human Ureter either Healthy or Fitted with Double-Pigtail Stent or a Thin 0.3?F Suture Thread: A Preliminary Study

机译:人类输尿管中的组织学炎症要么健康或配有双尾桩支架或薄0.3缝合线:初步研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background. Ureteral stent intolerance reduces patients’ quality of life. It has been suggested that changes in the shape of stents could decrease discomfort. In previous studies, the innovative pigtail-suture stent (i.e., JFil? or MiniJFil?) with a thin 0.3?F suture thread significantly decreased stent-related symptoms. Fortuitously, a dilation of the ureter containing the sutures was discovered. In addition, no inflammation was seen on the ureter wall around the suture in endoscopy. In this preliminary study, we assessed ureteral inflammation in the human ureter when it was healthy or when fitted with a double-pigtail stent or a thread. Materials and Methods. After consent and inclusion of patients in the protocol, fifteen segments of ureters were collected during cystectomy procedures for bladder tumors. Ureteral inflammation was assessed on the histological section stained with hematoxylin-eosin. Histological grading (cumulative range of 0 to 6) assessing inflammation was performed on the ureter section for mucosa inflammation and inflammation in the muscle layer. Results. A marked ureteral inflammatory reaction was observed in all cases of ureters fitted with a double-pigtail stent with a mean inflammation score of 4.8?±?0.4. The ureter fitted with the thin suture thread showed inflammation in only one case with a mean inflammation score of 1.8?±?1.3 p=0.001. Conclusion. Although the study was limited by the small number of patients, it confirmed that the double-pigtail stent induced ureteral inflammation in all cases and the thin 0.3?F suture thread caused less ureteral inflammation than the double-pigtail stent. The concept of material reduction within the urinary tract seems necessary in order to decrease mucosal irritation. The JFil? or the MiniJFil? thread could meet this requirement.
机译:背景。输尿管支架不耐受降低患者的生活质量。已经提出了支架形状的变化可能会降低不适。在以前的研究中,创新的猪尾水支架(即,JFIL?或MINIJFIL?)具有薄的0.3?F缝线螺纹显着降低了支架相关的症状。偶然地,发现了含有缝合线的输尿管的扩张。此外,在内窥镜检查的缝合线周围的输尿管壁上没有看到炎症。在这项初步研究中,我们在健康或装配双尾纤支架或螺纹时评估人类输尿管中的输尿管炎。材料和方法。在同意并将患者纳入方案后,在膀胱切除术治疗膀胱肿瘤的过程中收集了15分段。评估输尿管炎症对用苏木精 - 曙红染色的组织学部分进行评估。在粘膜炎症和肌肉层中炎症的输尿管部分进行评估炎症的组织学分级(0至6的累积范围)。结果。在所有尿素中占用双猪支架的所有患者的出现明显的输尿管炎症反应,其炎症得分为4.8?±0.4。用薄缝线螺纹装配的输尿管仅在一个情况下显示出炎症,其炎症得分为1.8?±1.3 p = 0.001。结论。虽然该研究受到少数患者的限制,但它证实了双尾茎支架在所有情况下引起输尿管炎症,薄的0.3?F缝线螺纹比双尾巴支架均导致输尿管炎症较小。泌尿道内物质减少的概念似乎是有必要的,以减少粘膜刺激。 jfil?还是minijfil?线程可以满足这个要求。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号