首页> 外文期刊>Aerosol and Air Quality Research >Dilution Ratio and Particle Loss Performance of a Newly Developed Ejector Porous Tube Diluter Compared to a Commercial Diluter
【24h】

Dilution Ratio and Particle Loss Performance of a Newly Developed Ejector Porous Tube Diluter Compared to a Commercial Diluter

机译:与商业稀释剂相比,新开发的喷射器多孔管稀释剂的稀释比和颗粒损失性能

获取原文

摘要

In this study, a new ejector-porous tube diluter was developed to accurately in situ measure particulate matter at the source, e.g., emissions at coal-fired power plants, and its dilution ratio and particle loss were compared to those of a commercial model. Whereas commercial models supply air to the porous tube diluter (PRD) using a high-pressure compressor, our device replaces the latter with a ring blower, thereby decreasing the power consumption for the same airflow rate. As a demonstration, particle size volume distributions of fly ash at a coal-fired power plant stack were determined for different dilution ratios. PRD flow rates of 10 and 20 L min–1 for the commercial diluter produced ~2-μm particle volume concentrations of 382 and 572 μm3 cm–3, respectively, from an initial (undiluted) volume concentration of 756 μm3 cm–3. However, PRD flow rates of 10 and 30 L min–1 for the developed device produced ~2-μm particle volume concentrations of 506 and 500 μm3 cm–3, respectively, from an initial volume concentration of 532 μm3 cm–3. These particle loss rates were confirmed through field testing.
机译:在该研究中,在源极其测量颗粒物质的新喷射器多孔管稀释剂,例如,燃煤发电厂的排放,以及其稀释比和颗粒损失与商业模型的渗透率。然而,商业型号使用高压压缩机向多孔管稀释剂(PRD)供应空气,我们的装置用戒指鼓风机取代后者,从而降低相同的气流率的功耗。作为示范,针对不同的稀释比测定燃煤发电厂堆栈处的粉煤灰的粒度体积分布。商业稀释剂的10和20L min-1的PRD流速分别产生〜2微米的粒子体积浓度为382和572μm3cm-3,从初始(未稀释的)体积浓度为756μm3cm-3。然而,PRD流量为10和30 L min-1的开发装置,分别从初始体积浓度为532μm3cm-3的初始体积浓度产生〜2μm颗粒体积浓度。这些颗粒损失率通过现场测试确认。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号