Purpose: In limbal stem cell deficiency, both the Ocular Surface Disease Index (OSDI) questionnaire and tear break-up time (BUT) are comparable between traditional methods and the Keratograph 5M. In this study, we aimed to correlate OSDI with Keratograph 5M interviewed OSDI, as well as slit-lamp tear BUT with Keratograph 5M noninvasive tear break-up time (NIKBUT) in limbal stem cell deficiency. Patients and methods: Thirty-eight limbal stem cell-deficiency patients (76 eyes) from Virgen Macarena-Rocio Hospital (Seville, Spain) underwent this diagnostic test study. All patients completed the traditional OSDI. We measured the BUT, performed a Keratograph 5M analysis of NIKBUT first (employed for the analysis) followed by the average NIKBUT, the level of dryness, and conducted the OSDI questionnaire through an interview. For each pair of tests, we analyzed the means and applied an intraclass correlation coefficient ( r ), creating a Bland-Altman plot for data dispersion. Results: Average values were 47.5 points (±25.8), and 47.3 points (±27.5) for traditional OSDI and Keratograph OSDI, respectively ( P =0.87); the r value indicates good agreement (0.72). The Bland-Altman plot followed a linear pattern, and the results were similarly distributed. The NIKBUT mean was shorter than the BUT mean ( P = 0.007); the r value indicates moderate agreement (0.574). The Bland-Altman plot formed an almost horizontal line, with almost all values between the mean and two standard deviations. Conclusion: Keratograph 5M is useful for the evaluation of the ocular surface in limbal stem cell deficiency. NIKBUT can substitute BUT based on its advantages of being noninvasive, objective, with intraobserver and interobserver repeatability and reliability. The Keratograph 5M OSDI is comparable to the traditional questionnaire.
机译:目的:在恒星干细胞缺乏,眼部表面疾病指数(OSDI)问卷和撕裂分段时间(但)在传统方法和角图5M之间是可比的。在这项研究中,我们旨在将OSDI与Keratober 5M采访的OSDI相关联,以及狭缝射灯,但随着朗巴尔5M非侵入性撕裂时间(Nikbut)的狭缝射流缺陷。患者和方法:来自Virgen Macarena-Rocio医院(西班牙塞维利亚,西班牙)的三十八根斜纹干细胞缺乏症患者(76只眼)接受了这种诊断测试研究。所有患者均完成传统的OSDI。我们测量了,但是,对Nikbut的第一次(用于分析)进行了角震5M分析,然后是平均NikBut,干燥水平,并通过面试进行OSDI问卷。对于每对测试,我们分析了手段并应用了跨站相关系数(R),为数据分散创建了一个Bland-Altman曲线图。结果:平均值为47.5点(±25.8),以及传统OSDI和角图OSDI的47.3点(±27.5)(P = 0.87); R值表示良好的协议(0.72)。 Bland-Altman绘图遵循线性模式,结果类似地分布。尼克丁平均值短于但平均值短(p = 0.007); R值表示适度协议(0.574)。 Bland-Altman绘图形成了几乎水平的线路,几乎所有的值与两个标准偏差之间几乎所有值。结论:角镜5M可用于评估尾骨干细胞缺乏的眼表面。 NikBut可以替代,但基于其非侵入性,目标的优点,具有跨内机和Interobserver可重复性和可靠性。 Keratograph 5M OSDI与传统问卷相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号