首页> 外文期刊>Clinical ophthalmology >Relative sensitivity and specificity of 10-2 visual fields, multifocal electroretinography, and spectral domain optical coherence tomography in detecting hydroxychloroquine and chloroquine retinopathy
【24h】

Relative sensitivity and specificity of 10-2 visual fields, multifocal electroretinography, and spectral domain optical coherence tomography in detecting hydroxychloroquine and chloroquine retinopathy

机译:10-2个视野,多焦电流术和光谱域光学相干断层扫描在检测羟基氯喹和氯喹抗视网膜病变中的相对敏感性和特异性

获取原文
           

摘要

Background: The purpose of this study was to determine the relative sensitivity and specificity of 10-2?visual fields (10-2?VFs), multifocal electroretinography (mfERG), and spectral domain optical coherence tomography (SD-OCT) in detecting hydroxychloroquine retinopathy.Methods: A total of 121?patients taking hydroxychloroquine (n=119) or chloroquine (n=2) with 10-2?VF, mfERG, and SD-OCT tests were retrospectively reviewed. Rates of test abnormality were determined.Results: Retinopathy was present in 14?and absent in 107. Eleven of 14?(78.6%) patients with retinopathy were overdosed. Twelve (85.7%) had cumulative dosing greater than 1,000?g. The sensitivities of 10-2?VF, mfERG, and SD-OCT in detecting retinopathy were 85.7%, 92.9%, and 78.6%, respectively. The specificities of 10-2?VF, mfERG, and SD-OCT in detecting retinopathy were 92.5%, 86.9%, and 98.1%, respectively. Positive predictive values of 10-2?VF, mfERG, and SD-OCT in detecting retinopathy were less than 30% for all estimates of hydroxychloroquine retinopathy prevalence. Negative predictive values were >99% for all tests.Conclusion: Based on published estimates of hydroxychloroquine retinopathy prevalence, all three tests are most reliable when negative, allowing confident exclusion of retinopathy in patients taking ≤6.5?mg/kg/day. Each test is less useful in allowing a confident diagnosis of retinopathy when positive, especially in patients taking ≤6.5?mg/kg/day.
机译:背景:本研究的目的是确定10-2的相对敏感性和特异性(10-2 vFS),多焦电型造影(MFERG),以及探测羟氯喹的光谱域光学相干断层扫描(SD-OCT)检查疗法:共有121例?羟基氯喹(n = 119)或氯喹(n = 2)的患者回顾性地审查了10-2〜vf,mfftg和SD-OCT测试。测定了测试异常的率。结果:视网膜病患者在14中存在,107中缺席14岁?(78.6%)过度过度过滤患有视网膜病变的患者。十二(85.7%)的累积剂量大于1,000?g。检测视网膜病变10-2 vf,mff,sd-oct的敏感性分别为85.7%,92.9%和78.6%。检测视网膜病变为10-2 vf,mff,sd-oct的特异性分别为92.5%,86.9%和98.1%。对于羟基氯喹的所有估计,阳性预测值10-2?VF,MFERG和SD-OCT在羟基氯喹患病率普及的所有估计的30%。所有测试的负面预测值> 99%。结论:基于发表的羟基氯喹患病率患病率,所有三种测试最可靠,允许相信患者≤6.5?mg / kg /天的视网膜病变。当阳性时,每种测试均不太有用,尤其是在患者≤6.5?mg / kg /天的患者中,允许自信地诊断视网膜病变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号