首页> 外文期刊>BMC Musculoskeletal Disorders >Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position
【24h】

Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position

机译:膝关节伸展强度测量的可靠性和有效性使用仰卧位的便携式测功机锚固系统

获取原文

摘要

Muscle strength measurements using hand-held dynamometry (HHD) can be affected by the inadequate strength of the tester and lack of stabilization of the participants and the device. A portable HHD anchoring system was designed that enabled the measurement of isometric knee extensor muscle strength in a supine position. This can be used with individuals who are unable to assume the sitting position required for the measurement of knee extensor strength in conventional isokinetic dynamometry (IKD). The aim of this study was to evaluate the reliability and validity of knee extensor strength measurements using this device. The maximal knee extensor isometric strength of the dominant leg in healthy adults aged 20 to 40?years was tested. Three trials of three contractions were assessed by two raters using the portable dynamometer anchoring system whilst the participant was in the supine position. After the three measurement trials, peak knee extensor torque was evaluated using IKD. The intraclass correlation coefficient (ICC) and 95% limits of agreement (LOA) for intra- and inter-rater reliability were obtained. Thirty-nine participants (19 male and 20 female, aged 30.08?±?4.16 y), completed the three measurement trials. The ICC for intra-rater reliability was 0.98 for the maximum measurements of knee extensor strength (95% confidence interval [CI]: 0.96-0.98) and 0.98 (95% CI: 0.96-0.99) for inter-rater reliability. The mean difference (%) between the maximum knee extensor strength measurements of each trial was 1.02% (LOA range: -?11.13 to 13.16%) for intra-rater and?-?1.44% (LOA range: -?13.98 to 11.08%) for inter-rater measurements. The Pearson correlation coefficient of the maximum voluntary peak torque measurements with the portable dynamometer anchoring system and IKD was 0.927. The portable dynamometer anchoring system is a reliable and valid tool for measuring isometric knee extensor strength in a supine position. Future clinical feasibility studies are needed to determine if this equipment can be applied to people with severe illness or disabilities. KCT0003041 .
机译:使用手持动力测量法(HHD)的肌肉力量测量可能受到测试仪强度不足的影响,并且缺乏参与者和设备的稳定性。设计了便携式HHD锚固系统,使得能够以仰卧位测量等距膝关节伸肌肌肉强度。这可以与不能假设在传统的等因动力学(IKD)中测量膝关节延伸强度所需的坐姿所需的个体。本研究的目的是评估使用该装置的膝盖延伸强度测量的可靠性和有效性。在20至40岁的健康成年人身上的最大膝盖伸肌等距强度进行了测试。通过使用便携式测力计锚固系统的两个评分器评估三次收缩的三次试验,同时参与者处于仰卧位。在三次测量试验之后,使用IKD评估峰值膝盖延伸扭矩。获得了与帧内间可靠性有关和帧间间可靠性的脑内相关系数(ICC)和95%限制。三十九名参与者(19名男性和20名女性,年龄30.08岁?±4.16岁),完成了三项测量试验。对于膝关节伸长强度的最大测量(95%置信区间[CI]:0.96-0.98)和0.98(95%CI:0.96-0.99),ICC为ratlar-rater-rater-rater的可靠性为0.98。每个试验的最大膝盖延伸强度测量的平均差异(%)为1.02%(LOA范围: - α11.13至13.16%)用于叙述 - ? - ?1.44%(LOA范围: - ?13.98至11.08% )对于帧间测量。具有便携式测功机锚固系统和IKD的最大自愿峰值扭矩测量的Pearson相关系数为0.927。便携式测力计锚固系统是一种可靠且有效的工具,用于在仰卧位置测量等距膝关节伸展强度。需要未来的临床可行性研究来确定该设备是否可以应用于严重疾病或残疾的人。 KCT0003041。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号