...
首页> 外文期刊>Journal of Clinical Microbiology >Detection of bacteriuria and pyuria by URISCREEN a rapid enzymatic screening test.
【24h】

Detection of bacteriuria and pyuria by URISCREEN a rapid enzymatic screening test.

机译:通过尿素筛选尿素尿素筛选试验的噬菌体和脓尿。

获取原文

摘要

A multicenter study was performed to evaluate the ability of the URISCREEN (Analytab Products, Plainview, N.Y.), a 2-min catalase tube test, to detect bacteriuria and pyuria. This test was compared with the Chemstrip LN (BioDynamics, Division of Boehringer Mannheim Diagnostics, Indianapolis, Ind.), a 2-min enzyme dipstick test; a semiquantitative plate culture method was used as the reference test for bacteriuria, and the Gram stain or a quantitative chamber count method was used as the reference test for pyuria. Each test was evaluated for its ability to detect probable pathogens at greater than or equal to 10(2) CFU/ml and/or greater than or equal to 1 leukocyte per oil immersion field, as determined by the Gram stain method, or greater than 10 leukocytes per microliter, as determined by the quantitative count method. A total of 1,500 urine specimens were included in this evaluation. There were 298 specimens with greater than or equal 10(2) CFU/ml and 451 specimens with pyuria. Of the 298 specimens with probable pathogens isolated at various colony counts, 219 specimens had colony counts of greater than or equal to 10(5) CFU/ml, 51 specimens had between 10(4) and 10(5) CFU/ml, and 28 specimens had between 10(2) and less than 10(4) CFU/ml. Both the URISCREEN and the Chemstrip LN detected 93% (204 of 219) of the specimens with probable pathogens at greater than or equal to 10(5) CFU/ml. For the specimens with probable pathogens at greater than or equal to 10(2) CFU/ml, the sensitivities of the URISCREEN and the Chemstrip LN were 86% (256 of 298) and 81% (241 of 298), respectively. Of the 451 specimens with pyuria, the URISCREEN detected 88% (398 of 451) and Chemstrip LN detected 78% (350 if 451). There were 204 specimens with both greater than or equal to 10(2) CFU/ml and pyuria; the sensitivities of both methods were 95% (193 of 204) for these specimens. Overall, there were 545 specimens with probable pathogens at greater than or equal to 10(2) CFU/ml and/or pyuria. The URISCREEN detected 85% (461 of 545), and the Chemstrip LN detected 73% (398 of 545). A majority (76%) of the false-negative results obtained with either method were for specimens without leukocytes in the urine. There were 955 specimens with no probable pathogens or leukocytes. Of these, 28% (270 of 955) were found positive by the URISCREEN and 13% (122 of 955) were found positive by the Chemstrip LN. A majority of the false-positive results were probably due, in part, to the detection of enzymes present in both bacterial and somatic cells by each of the test systems. Overall, the URISCREEN is rapid, manual, easy-to-perform enzymatic test that yields findings similar to those yielded by the Chemstrip LN for specimens with both greater than or equal to 10(2) CFU/ml and pyuria or for specimens with greater than or equal to 10(5) CFU/ml and with or without pyuria. However, when the data were analyzed for either probable pathogens at less 10(5) CFU/ml or pyuria, the sensitivity of the URISCREEN was higher (P less than 0.05).
机译:进行多中心研究以评估尿素(分析产品,Plainview,N.Y.),2分钟过氧化酶管试验,检测细菌和脓尿的能力。将该测试与ChemStrip LN(Boehringer Mannheim Diagnostics,Indianapolis,Ind)进行比较。使用半敏化板培养方法作为噬菌体的参考试验,并且使用革兰斑或定量室计数方法作为Pyuria的参考测试。评价每种试验的能力,其能够以大于或等于10(2)CFU / mL和/或大于或等于1只有浸没物体,或者由革兰污染方法或大于每微升10只白细胞,由定量计数法测定。该评估中共有1,500种尿样。有298个标本,具有大于或等于10(2)CFU / ml和451个样品,具有脓尿。在具有在各种菌落计数下分离的可能病原体的298个标本中,219个样本的菌落计数大于或等于10(5)CFU / mL,51个样本在10(4)和10(5)CFU / mL之间,和28个标本在10(2)且小于10(4)CFU / mL之间。 Uriscreen和ChemStrip LN都检测到93%(204个219个)的试样,具有大于或等于10(5)CFU / mL的可能性病原体。对于具有大于或等于10(2)CFU / mL的可能病原体的样品,尿素抑制和化学LN的敏感性分别为86%(256个)和81%(298个中的298个)。在具有脓电尿的451个标本中,尿素素检测到88%(398个451个)和化学LN检测到78%(350个IF 451)。有204个样品,两者均大于或等于10(2)CFU / mL和Pyuria;这些样品的两种方法的敏感性为95%(193的204例)。总体而言,有545个标本具有可能的病原体,大于或等于10(2)CFU / mL和/或Pyuria。尿素检测到85%(461个,共545个),ChemStrip LN检测到73%(545个中的398个)。用任一方法获得的大多数(76%)的假阴性结果是尿液中没有白细胞的标本。有955个标本没有可能的病原体或白细胞。其中,28%(270个中的955个)被尿素阳性发现阳性,ChemStrip LN发现13%(122个)阳性。部分假阳性结果可能是由于每个测试系统检测在细菌和体细胞中存在的酶。总的来说,尿素是快速的,手动,易于进行的酶促测试,其产生类似于由化学LN产生的结果,该样品具有大于或等于10(2)CFU / mL和Pyuria或具有更大的标本含有或等于10(5)个CFU / ml,有或没有脓尿。然而,当在较少的10(5)CFU / mL或Pyuria下分析可能的病原体的数据时,尿素的敏感性更高(P小于0.05)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号