首页> 外文期刊>Scientific reports. >Quantification of radioactivity by planar gamma-camera images, a promoted method of absorbed dose in the thyroid after iodine-131 treatment
【24h】

Quantification of radioactivity by planar gamma-camera images, a promoted method of absorbed dose in the thyroid after iodine-131 treatment

机译:通过平面伽玛照相机图像对放射性进行定量,这是碘131治疗后甲状腺吸收剂量的一种促进方法

获取原文
           

摘要

Iodine-131 (131I) is an essential and widely used radioisotope in thyroid diseases and animal experiments. Planar imaging has been considered the most popular method for 131I thyroid uptake radioactive activity quantification. The ROI defining section is essential and can affect the accuracy of quantitative results. However, a consistent method has not been proposed. In this study, a UC-ROI defining method based on ULWL setting and colour display grade was applied. Three steps were performed: image acquisition of five standard activity models and obtaining the exact value that the counts per radioactive activity contributes to the ROI; image acquisition of 20 rat thyroids and obtaining the counts of the ROI (thyroid); and calculating the rat thyroid radioactive activity and comparing these values with the true values. The accuracy of quantification activity of 131I in rat thyroid reached 2.62%?±?0.41%. The mean quantification within 5% could be achieved in 19 of 20 rat thyroids. No significant difference existed between calculated thyroid 131I activity and true values with a paired matched-test (t?=??0.384, P?=?0.706??0.05). The results indicated that with the UC-ROI defining method, more accurate thyroid uptake 131I radioactive activity quantification by SPECT planar imaging can be achieved in vivo rat study.
机译:碘131(131I)是甲状腺疾病和动物实验中必需的且广泛使用的放射性同位素。平面成像已被认为是131I甲状腺摄取放射性活度量化的最流行方法。 ROI定义部分至关重要,可能会影响定量结果的准确性。但是,尚未提出一致的方法。在这项研究中,应用了基于ULWL设置和彩色显示等级的UC-ROI定义方法。进行了三个步骤:五个标准活动模型的图像获取,以及获得每个放射性活度计数对ROI贡献的确切值;采集20只大鼠甲状腺的图像并获得ROI(甲状腺)的计数;计算大鼠甲状腺的放射性活性并将这些值与真实值进行比较。大鼠甲状腺中131I定量活性的准确度达到2.62%±±0.41%。 20只大鼠甲状腺中有19只甲状腺的平均定量在5%以内。配对的配对测试结果显示,计算出的甲状腺131I活性与真实值之间无显着差异(t?=?0.384,P?=?0.706?>?0.05)。结果表明,使用UC-ROI定义方法,可以在体内大鼠研究中通过SPECT平面成像更准确地定量甲状腺摄取131I放射性活性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有