Recovery rates of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens were determined by using the fluorescent BACTEC 9000 MB system. Data were compared to those assessed by the radiometric BACTEC 460 system and by cultivation on solid media. A total of 3,095 specimens were processed with N-acetyl-L-cysteine-NaOH by two laboratories. The contamination rates for the BACTEC 9000 MB system were 6.8% (center 1) and 9.8% (center 2). A total of 451 mycobacterial isolates were detected (Mycobacterium tuberculosis complex, n = 296; nontuberculous mycobacteria [NTM], n = 155). These isolates originated from 94 (20.8%) smear-positive and 357 (79.2%) smear-negative specimens. The BACTEC 9000 MB system was significantly better than solid media (P < 0.05) in detecting AFB, but it was less efficient than the radiometric system (P < 0.01). The BACTEC 9000 MB system plus solid media (combination A) recovered 393 (87.1%) of the isolates, while the BACTEC 460 system plus solid media (combination B) detected 430 (95.3%) of all AFB isolates. Between combination A and B there was no statistically significant difference for the detection of isolates from smear-positive specimens (P > 0.05), in contrast to the recovery of AFB from smear-negative specimens for M. tuberculosis complex, P < 0.05; for NTM, P < 0.01). The mean time to detection of M. tuberculosis complex was 12.2 days for smear-positive specimens and 18.1 days for smear-negative specimens with the BACTEC 9000 MB system; 9.3 and 15.6 days, respectively, with the BACTEC 460 system; and 21.2 and 28.4 days, respectively, with solid media. For NTM, the average detection times were 15.1, 17.3, and 31.3 days by the three methods, respectively. In conclusion, the BACTEC 9000 MB system is a rapid, less labor-intensive detection system which allows for higher levels of recovery of AFB than solid media. There is no risk of cross contamination, which is known to be the case for the BACTEC 460 system, and data management is greatly facilitated. As a whole, however, the BACTEC 9000 MB system should only be used in conjunction with solid media.
机译:使用荧光BACTEC 9000 MB系统确定抗酸杆菌(AFB)的回收率以及从临床标本中检出它们的平均时间。将数据与通过辐射BACTEC 460系统评估并在固体培养基上培养的数据进行比较。由两个实验室用N-乙酰基-L-半胱氨酸-NaOH处理了总共3,095个样品。 BACTEC 9000 MB系统的污染率分别为6.8%(中心1)和9.8%(中心2)。总共检测到451株分枝杆菌(结核分枝杆菌复合体,n = 296;非结核分枝杆菌[NTM],n = 155)。这些分离株来自94个(20.8%)涂片阳性标本和357个(79.2%)涂片阴性标本。 BACTEC 9000 MB系统在检测AFB方面显着优于固态介质(P <0.05),但其效率低于辐射测量系统(P <0.01)。 BACTEC 9000 MB系统加固体培养基(组合A)回收了393个菌株(87.1%),而BACTEC 460系统加固体培养基(组合B)检测到了所有AFB菌株430个(95.3%)。在组合A和组合B之间,从涂片阳性标本中分离出的分离物的检测没有统计学上的显着差异(P> 0.05),而结核分枝杆菌复合物从涂片阴性标本中回收的AFB则相反,P <0.05;对于NTM,P <0.01)。使用BACTEC 9000 MB系统检测涂片阳性标本的平均时间为12.2天,涂片阴性标本的平均时间为18.1天。 BACTEC 460系统分别为9.3天和15.6天;固体培养基分别为21.2天和28.4天。对于NTM,三种方法的平均检测时间分别为15.1、1、3和31.3天。总之,BACTEC 9000 MB系统是一种快速,省力的检测系统,与固体介质相比,AFB的回收率更高。 BACTEC 460系统不存在交叉污染的风险,大大简化了数据管理。总体而言,BACTEC 9000 MB系统仅应与固态介质结合使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号