首页> 外文期刊>Journal of Clinical Microbiology >Comparison of MB/BacT ALERT 3D System with Radiometric BACTEC System and L?wenstein-Jensen Medium for Recovery and Identification of Mycobacteria from Clinical Specimens: a Multicenter Study
【24h】

Comparison of MB/BacT ALERT 3D System with Radiometric BACTEC System and L?wenstein-Jensen Medium for Recovery and Identification of Mycobacteria from Clinical Specimens: a Multicenter Study

机译:MB / BacT ALERT 3D系统与辐射BACTEC系统和L?wenstein-Jensen培养基用于从临床标本中恢复和鉴定分枝杆菌的比较:一项多中心研究

获取原文
           

摘要

The MB/BacT ALERT 3D System (MB/BacT) (Organon Teknika, Boxtel, The Netherlands) is a fully automated, nonradiometric system with a revised antibiotic supplement kit designed for the recovery of mycobacteria from clinical specimens. In a multicenter study, the recovery rate of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens was determined by using the MB/BacT system. Data were compared to those assessed by the radiometric BACTEC 460 system (B460) and by culture on L?wenstein-Jensen (L-J) solid medium. A total of 2,859 respiratory and extrapulmonary specimens were processed by the N-acetyl-l-cysteine (NALC)-NaOH method using two different concentrations of sodium hydroxide; 1.5% was adopted in study design A (1,766 specimens), and 1.0% was used in study design B (1,093 specimens). The contamination rates for MB/BacT were 4.6% (study design A) and 7.1% (study design B). One hundred seventy-nine mycobacterial isolates were detected by study design A, with 148 Mycobacterium tuberculosis complex (MTB) isolates and 31 nontuberculous mycobacteria (NTM) isolates. Overall recovery rates were 78.8% for MB/BacT (P = 0.0049), 64.2% for L-J (P < 0.0001), and 87.1% for B460, whereas they were 84.5, 70.9, and 91.2%, respectively, for MTB alone. A total of 125 mycobacteria were detected by study design B, with 46 MTB and 79 NTM. Overall recovery rates by the individual systems were 57.6% (P = 0.0002), 56.8% (P = 0.0001), and 80% for MB/BacT, L-J, and B460, respectively, whereas the rates were 91.3, 78.3, and 97.8% for MTB alone. By study design A, the mean times to detection of smear-positive MTB, smear-negative MTB, and NTM were 11.5, 19.9, and 19.6 days, respectively, with the MB/BacT; 8.3, 16.8, and 16.6 days, respectively, with the B460; and 20.6, 32.1, and 27.8 days, respectively, with L-J medium. By study design B, the mean times were 15.1, 26.7, and 26 days with the MB/BacT; 11.7, 21.3, and 24.8 days with the B460; and 20.4, 28.7, and 28.4 days with L-J medium. Identification was attempted by probing (Accuprobe) MB/BacT-positive bottles within the first working day following instrument positive flag. Results were compared to those obtained in the B460 positive vials by thep-nitro-α-acetylamino-β-hydroxypropiophenone (NAP) test (study design A) or by the Accuprobe assay (study design B). About 90% of MTB and 100% of NTM could be identified, showing turnaround times closely related to those obtained by combining B460 and the NAP test or the Accuprobe assay. In conclusion, even though recovery rates were shown to be lower than B460, especially for NTM, and contaminants were somewhat higher, MB/BacT represents a valuable alternative to the radiometric system, especially in those laboratories where disposal of radioactive waste is restricted. Finally, when AFB are cultured in nonradiometric liquid media, our data (detection times and bacterial overgrowth rates) suggest that decontamination with 1.5% NaOH may be more suitable than the standard NALC-NaOH.
机译:MB / BacT ALERT 3D系统(MB / BacT)(荷兰Boxtel的Organon Teknika)是一种完全自动化的非放射线系统,带有经过改良的抗生素补充剂套件,用于从临床标本中恢复分枝杆菌。在一项多中心研究中,使用MB / BacT系统确定了耐酸杆菌(AFB)的回收率和从临床标本中检出它们的平均时间。将数据与通过辐射BACTEC 460系统(B460)和在L?wenstein-Jensen(L-J)固体培养基上培养得到的数据进行比较。使用两种不同浓度的氢氧化钠,通过 N -乙酰基-1-半胱氨酸(NALC)-NaOH方法处理了总共2,859个呼吸道和肺外标本。研究设计A采用1.5%(1,766个样本),研究设计B使用1.0%(1,093个样本)。 MB / BacT的污染率为4.6%(研究设计A)和7.1%(研究设计B)。研究设计A检测了179株分枝杆菌,其中148株结核分枝杆菌复合物(MTB)分离株和31株非结核分枝杆菌(NTM)分离株。 MB / BacT( P = 0.0049)的总回收率为78.8%,LJ( P <0.0001)的总回收率为64.2%,B460为87.1%仅MTB分别为70.9%和91.2%。研究设计B总共检测到125个分枝杆菌,其中46个MTB和79个NTM。单个系统的总恢复率分别为57.6%( P = 0.0002),56.8%( P = 0.0001)和MB / BacT,LJ和B460的80% ,而仅MTB的比率分别为91.3、78.3和97.8%。根据研究设计A,MB / BacT检测涂片阳性MTB,涂片阴性MTB和NTM的平均时间分别为11.5、19.9和19.6天。 B460分别为8.3、16.8和16.6天; L-J培养基分别为20.6、32.1和27.8天。根据研究设计B,MB / BacT的平均时间为15.1、26.7和26天。使用B460的11.7、21.3和24.8天; L-J培养基分别为20.4、28.7和28.4天。尝试在仪器阳性标志发出后的第一个工作日内通过探测(Accuprobe)MB / BacT阳性瓶进行鉴定。通过 p -硝基-α-乙酰氨基-β-羟基苯乙酮(NAP)测试(研究设计A)或Accuprobe分析(研究设计B),将结果与B460阳性小瓶中的结果进行比较。 。可以识别出大约90%的MTB和100%NTM,其周转时间与通过结合B460和NAP测试或Accuprobe分析获得的周转时间密切相关。总之,尽管已证明回收率低于B460,尤其是对于NTM而言,并且污染物有所提高,但是MB / BacT还是放射性系统的一种有价值的替代品,尤其是在放射性废物处置受到限制的实验室中。最后,当在非辐射液体介质中培养AFB时,我们的数据(检测时间和细菌过度生长率)表明,用1.5%NaOH净化比标准NALC-NaOH更合适。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号