首页> 外文期刊>Journal of Clinical Microbiology >Comparison of PCR- and Hybrid Capture-Based Human Papillomavirus Detection Systems Using Multiple Cervical Specimen Collection Strategies
【24h】

Comparison of PCR- and Hybrid Capture-Based Human Papillomavirus Detection Systems Using Multiple Cervical Specimen Collection Strategies

机译:基于PCR和杂交捕获的人乳头瘤病毒检测系统使用多种宫颈标本采集策略的比较

获取原文
           

摘要

This study compared the performances of three human papillomavirus (HPV) detection tests with specimens collected by three alternative procedures. The HPV tests included the Hybrid Capture Tube test (HCT), the microplate-based Hybrid Capture II test (HC II), and the MY09-MY11 L1 consensus primer PCR-based assay. Initial cervical specimens were collected from study subjects with a broom device, and after Papanicolaou smears were made, residual specimens were placed into PreservCyt (PC), a liquid cytology medium. A second specimen was collected from each subject and placed into Digene Specimen Transport Medium (STM). The device for collection of the second specimen alternated with consecutive subjects between a conical cytology brush and a Dacron swab. At the 1.0-pg/ml cutoff, the results of the HC II agreed well with those of the PCR. Specifically, when PCR data were restricted to the types found by the HC II (HPV types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, and 68), there was greater than 90% agreement between the HC II and PCR results with both STM and PC. At a lower cutoff (0.2 pg/ml), HC II-positive results increased further, especially when the test was applied to the PC specimens. However, false-positive HC II results were more often observed at the 0.2-pg/ml cutoff. HC II yielded the highest HPV positivity with specimens placed into PC, followed by specimens collected with a conical brush and placed into STM and, last, by those collected with a Dacron swab and placed into STM. Our results demonstrate the utility of both the STM and PC specimen collection methods and show good agreement between the HC II and PCR.
机译:这项研究将三种人类乳头瘤病毒(HPV)检测测试的性能与通过三种替代程序收集的标本进行了比较。 HPV测试包括杂交捕获管测试(HCT),基于微孔板的杂交捕获II测试(HC II)和基于MY09-MY11 L1共有引物PCR的检测。用扫帚装置从研究对象中收集最初的宫颈标本,并在涂上帕潘尼古拉涂片后,将残留的标本放入液体细胞学培养基PreservCyt(PC)中。从每个受试者收集第二个标本,并将其放入Digene标本运输介质(STM)中。用于收集第二个标本的设备与在锥形细胞学刷和Dacron拭子之间的连续对象交替出现。在1.0 pg / ml的临界值下,HC II的结果与PCR的结果非常吻合。具体来说,当PCR数据仅限于HC II发现的类型(HPV类型16、18、31、33、35、39、45、51、52、56、58、59和68)时, HC II和PCR结果与STM和PC的一致性达到90%。在较低的临界值(0.2 pg / ml)下,HC II阳性结果进一步增加,尤其是在对PC标本进行测试时。但是,HC-II假阳性结果在0.2-pg / ml的临界值下更常见。 HC II具有最高的HPV阳性率,将标本放入PC,然后用锥形刷收集标本并放入STM,最后,用Dacron棉签收集并放入STM。我们的结果证明了STM和PC标本采集方法的实用性,并显示了HC II和PCR之间的良好一致性。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号