Probe colorimeter for quantitating enzyme-linked immunosorbent assays and other colorimetric assays performed with microplates.

机译:探针比色计,用于定量酶联免疫吸附测定和其他用微孔板进行的比色测定。

获取原文
           

摘要

The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units.
机译:将光纤探针比色计(型号PC800; Brinkmann Instruments,Inc.,Westbury,NY)在96孔微量滴定板中定量酶促或比色测定的性能与分光光度计(型号240; Gilford Instrument Laboratories,Inc)进行了比较。 (俄亥俄州奥伯林(Oberlin))和市售的酶免疫分析仪(型号MR590;弗吉尼亚州亚历山大市的Dynatech Laboratories,Inc.)。在3 M NaOH中的碱性磷酸酶-对硝基苯基磷酸酯用作生色团来源。评估了六种类型的板与探针色度计一起使用;当一个人对每块板上相同的生色团稀释度进行24次独立测量时,他们产生的重现性值(100%变异系数)在91%到98%之间。 11个人分别用色度计在可见光的色度稀释度(在420 nm处的吸光度为0.10)或暗的(420 nm的吸光度为0.80)上进行了24次测量。浅稀释度的重现性平均值为87%,深色稀释度的重现性平均值为97%。当一个人在比色计,分光光度计或酶免疫分析仪中至少测量20次相同的生色团样品时,每种仪器的重现性均大于99%。在固定体积中对发色团的稀释系列进行的测量表明,每种仪器的光学响应在0.05至1.10吸光度单位的范围内都是线性的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号