Specimens submitted for diagnosis of herpes simplex virus (HSV) infection were inoculated into shell vials and reacted with a commercial DNA probe kit (Pathogene; Enzo Biochem, Inc., New York, N.Y.) and an immunofluorescence assay at 16 h postinoculation. The results were compared with isolation of the virus in conventional tube cell cultures. Of 504 specimens, 105 (20.8%) were positive for HSV. Of the 105, 93 HSV-positive specimens (89%) were detected by all three assay systems. Maximum detection of HSV (100 of 105 [95%]) was obtained by probe or monoclonal antibody assay in shell vials, which had sensitivities of 98 and 97%, respectively, compared with viral recovery in conventional tube cell cultures (mean time for recognition of cytopathic effects, 2 days). Both shell vial assays were 99% specific. The DNA probe kit may be used as an alternative to a monoclonal antibody and fluorescence assay in shell vials as a diagnostic method for rapid laboratory detection of HSV infection.
机译:将提交用于诊断单纯疱疹病毒(HSV)感染的标本接种到贝壳小瓶中,并与市售DNA探针试剂盒(Pathogene; Enzo Biochem,Inc.,New York,N.Y.)反应,并在接种后16小时进行免疫荧光测定。将结果与常规管细胞培养物中病毒的分离进行了比较。在504个样本中,有105个(20.8%)的HSV阳性。在这105个样本中,全部三个检测系统检测到93个HSV阳性标本(占89%)。通过探针或单克隆抗体分析可在外壳小瓶中获得最大的HSV检测(100个,占105 [95%]),与常规试管细胞培养中的病毒回收率相比,其敏感性分别为98%和97%(平均识别时间) (2天)。两种壳小瓶测定法都具有99%的特异性。 DNA探针试剂盒可以用作单克隆抗体的替代品,也可以用作外壳小瓶中的荧光检测试剂盒,作为快速检测HSV感染的诊断方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号