Potential hazards associated with microbial contamination of in-line filters during intravenous therapy.

机译:与静脉内过滤器内的微生物污染有关的潜在危害。

获取原文
           

摘要

The survival and multiplication of Enterobacter agglomerans, Klebsiella pneumoniae, Serratia marcescens, and Pseudomonas aeruginosa in 0.45- and 0.22-micrometer in-line filter sets during simulated infusions were studied to evaluate the ability of each filter type to prevent infusions of these bacteria into patients. Bacteria were found to proliferate in the upstream compartment of sets housing both filter porosities. None of the 0.22-micrometer in-line filters were penetrated by the test bacteria. In contrast, P. aeruginosa was observed to penetrate each 0.45-micrometer in-line filter examined within 12 h of continuous infusion. Tribe Klebsielleae organisms penetrated a proportion of the 0.45-micrometer filters usually between 48 and 72 h of infusion. In addition, the elution of endotoxin from gram-negative bacteria trapped in the filter set during infusion is reported. Collected infusion filtrate exhibited a trend of increasing endotoxin-like activity with an increasing duration of infusion. In the case of E. agglomerans, mean peak levels of approximately 65 pg of Escherichia coli endotoxin per ml were attained after 72 h. Other bacteria produced similar results, except mean peak levels ranged from 5 to 30 pg/ml. It was noted that endotoxin-like activity was not detected in filtrate eluted from contaminated filter sets during the initial 24 h of infusion. We conclude that to avoid potential hazards of bacterial penetration and endotoxin production during continuous use of in-line filter sets, the 0.22-micrometer filter type must be employed and replaced every 24 h.
机译:研究了在模拟输液过程中团聚肠杆菌,肺炎克雷伯菌,粘质沙雷氏菌和铜绿假单胞菌在0.45和0.22微米在线过滤器中的存活和繁殖,以评估每种过滤器防止将这些细菌注入患者的能力。 。发现细菌在容纳两个过滤器孔隙的组件的上游隔室中扩散。测试细菌不会穿透0.22微米的在线过滤器。相反,观察到铜绿假单胞菌在连续输注的12小时内穿透了每个0.45微米的在线过滤器。克雷伯氏菌属微生物通常在注入的48至72小时之间就渗透了一部分0.45微米的过滤器。另外,据报道,在输液过程中,捕获在过滤器中的革兰氏阴性细菌会洗脱内毒素。所收集的输注滤液显示出随着输注持续时间增加而增加内毒素样活性的趋势。对于团聚大肠杆菌,在72小时后达到了每毫升大约65 pg大肠杆菌内毒素的平均峰值水平。其他细菌产生相似的结果,除了平均峰值水平在5到30 pg / ml之间。注意到在输注的最初24小时内,从受污染的过滤器组洗脱的滤液中未检测到内毒素样活性。我们得出结论,为避免在连续使用在线过滤器组期间细菌渗透和产生内毒素的潜在危险,必须使用0.22微米的过滤器类型,并每24小时更换一次。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号