Aortic pulse wave velocity (PWV), calculated from pulse transit time (PTT) using 2 separate pulse recordings over a known distance, is a significant biomarker of cardiovascular risk. This study evaluates a novel method of determining PTT from waveform decomposition of central aortic pressure using a single pulse measurement. Aortic pressure was estimated from a transformed radial pulse and decomposed into forward and backward waves using a triangular flow wave. Pulse transit time was determined from cross-correlation of forward and backward waves. Pulse transit time, representing twice the PTT between 2 specific sites, was compared with independent measurements of carotid-femoral PTT in a cohort of 46 subjects (23 females; age 57±14 years). Linear regression between measured PTT (y; milliseconds) and calculated PTT (x; milliseconds) was y=1.05x?2.1 ( r =0.67; P <0.001). This model was tested in a separate group of 44 subjects (21 females; age 55±14 years) by comparing measured carotid-femoral PWV (y; meters per second) and PWV calculated using the estimated value of PTT (eTR/2) and carotid femoral distance (x; meters per second; y=1.21x?2.5; r =0.82; P <0.001). Findings indicate that the time lag between the forward and backward waves obtained from the decomposition of aortic pressure wave can be used to determine PWV along the aortic trunk and shows good agreement with carotid-femoral PWV. This technique can be used as a noninvasive and nonintrusive method for measurement of aortic PWV using a single pressure recording.
机译:主动脉脉搏波速度(PWV)是使用已知距离上的2个独立脉搏记录从脉搏传播时间(PTT)计算得出的,是心血管风险的重要生物标志。这项研究评估了一种使用单脉冲测量从中心主动脉压力的波形分解确定PTT的新方法。通过转换后的径向脉冲估算主动脉压力,并使用三角流波将其分解为前向波和后向波。脉冲传播时间是根据正向波和反向波的互相关来确定的。在一组46名受试者(23名女性;年龄57±14岁)中,将代表2个特定部位之间PTT两倍的脉搏传播时间与颈动脉PTT的独立测量值进行了比较。测量的PTT(y;毫秒)与计算的PTT(x;毫秒)之间的线性回归为y = 1.05x?2.1(r = 0.67; P <0.001)。通过比较测得的颈股PWV(y;米/秒)和使用PTT的估计值(eTR / 2)计算的PWV,在另一组44名受试者(21名女性; 55±14岁)中对该模型进行了测试。颈动脉距离(x;米/秒; y =1.21x≤2.5; r = 0.82; P <0.001)。研究结果表明,由主动脉压力波分解获得的前向波和后向波之间的时间差可用于确定沿主动脉干的PWV,并且与颈股PWV吻合良好。该技术可用作单次压力记录测量主动脉PWV的非侵入性和非侵入性方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号