Heart Rate Variability (HRV) is a well-known method to assess the human Autonomic Nervous System (ANS) functions. Currently, in the health care information system, HRV properties are very useful to provide medical and other vital signs of the patients. The HRV assessment was derived using the ECG R-R beat interval series, however, using the ECG probes with the electrode’s gel is not convenient for certain people such as who has an allergic symptom and or probes localization in front of the body part that needs certain knowledge how to put it on the correct location. Photoplethysmography (PPG) was considered to be an alternative way to assess HRV using the Peak-to-Peak interval series (PPI). Since previous studies already reported the availability to use PPG to assess HRV instead ECG, this study investigated how the HRV properties using those two methods during different postures with a fixed breathing pattern. Ten subjects participated in this study and we observed the R-R and the Peak-Peak beat interval time series from ECG and PPG respectively during sitting-supine, and standing-supine postures with 3 seconds breathing pattern. The results showed that using PPG to assess HRV still can be used with caution, especially during supine posture that had a deviation (SD) difference between ECG and PPG from the inter-subject analysis (p< 0.05). We concluded that the use of PPG still needs to be carefully considered to assess HRV properties, especially for wearable device and health care information system.
机译:心率变异性(HRV)是一种众所周知的评估人类自主神经系统(ANS)功能的方法。当前,在保健信息系统中,HRV特性对于提供患者的医疗和其他生命体征非常有用。 HRV评估是使用ECG RR搏动间隔系列得出的,但是,将ECG探头与电极凝胶一起使用对于某些人(例如有过敏症状或需要局部知识的探头定位在身体部位前部的人)不方便如何将其放置在正确的位置。光电容积描记术(PPG)被认为是使用峰-峰间隔序列(PPI)评估HRV的另一种方法。由于先前的研究已经报道了使用PPG代替HCG评估HRV的可行性,因此本研究调查了在固定呼吸模式的不同姿势下使用这两种方法的HRV特性。十名受试者参加了这项研究,我们观察了在坐仰卧位和站立仰卧位姿势(呼吸模式为3秒)期间ECG和PPG的R-R和Peak-Peak搏动间隔时间序列。结果表明,仍应谨慎使用PPG评估HRV,尤其是在仰卧位时,受试者之间的心电图和PPG值之间存在偏差(SD)差异(p <0.05)。我们得出的结论是,仍然需要认真考虑使用PPG来评估HRV特性,尤其是对于可穿戴设备和医疗保健信息系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号