...
首页> 外文期刊>Nucleic acids research >Measurement of 8-hydroxy-2′-deoxyguanosine in DNA by high-performance liquid chromatography-mass spectrometry: comparison with measurement by gas chromatography-mass spectrometry
【24h】

Measurement of 8-hydroxy-2′-deoxyguanosine in DNA by high-performance liquid chromatography-mass spectrometry: comparison with measurement by gas chromatography-mass spectrometry

机译:高效液相色谱-质谱法测定DNA中的8-羟基-2'-脱氧鸟苷:与气相色谱-质谱法比较

获取原文

摘要

Measurement of 8-hydroxy-2′-deoxyguanosine (8-OH-dGuo) in DNA by high-performance liquid chromatography/mass spectrometry (LC/MS) was studied. A methodology was developed for separation by LC of 8-OH-dGuo from intact and modified nucleosides in DNA hydrolyzed by a combination of four enzymes: DNase I, phosphodiesterases I and II and alkaline phosphatase. The atmospheric pressure ionization-electrospray process was used for mass spectral measurements. A stable isotope-labeled analog of 8-OH-dGuo was used as an internal standard for quantification by isotope-dilution MS (IDMS). Results showed that LC/IDMS with selected ion-monitoring (SIM) is well suited for identification and quantification of 8-OH-dGuo in DNA at background levels and in damaged DNA. The sensitivity level of LC/IDMS-SIM was found to be comparable to that reported previously using LC-tandem MS (LC/MS/MS). It was found that approximately five lesions per 106 DNA bases can be detected using amounts of DNA as low as 2 μg. The results also suggest that this lesion may be quantified in DNA at levels of one lesion per 106 DNA bases, or even lower, when more DNA is used. Up to 50 μg of DNA per injection were used without adversely affecting the measurements. Gas chromatography/isotope-dilution MS with selected-ion monitoring (GC/IDMS-SIM) was also used to measure this compound in DNA following its removal from DNA by acidic hydrolysis or by hydrolysis with Escherichia coli Fpg protein. The background levels obtained by LC/IDMS-SIM and GC/IDMS-SIM were almost identical. Calf thymus DNA and DNA isolated from cultured HeLa cells were used for this purpose. This indicates that these two techniques can provide similar results in terms of the measurement of 8-OH-dGuo in DNA. In addition, DNA in buffered aqueous solution was damaged by ionizing radiation at different radiation doses and analyzed by LC/IDMS-SIM and GC/IDMS-SIM. Again, similar results were obtained by the two techniques. The sensitivity of GC/MS-SIM for 7,8-dihydro-8-oxoguanine was also examined and found to be much greater than that of LC/MS-SIM and the reported sensitivity of LC/MS/MS for 8-OH-dGuo. Taken together, the results unequivocally show that LC/IDMS-SIM is well suited for sensitive and accurate measurement of 8-OH-dGuo in DNA and that both LC/IDMS-SIM and GC/IDMS-SIM can provide similar results.
机译:研究了通过高效液相色谱/质谱(LC / MS)测定DNA中的8-羟基-2'-脱氧鸟苷(8-OH-dGuo)。已开发出一种方法,用于通过LC分离由四种酶(DNase I,磷酸二酯酶I和II和碱性磷酸酶)水解的DNA中的完整和修饰核苷中的8-OH-dGuo。大气压电离-电喷雾过程用于质谱测量。稳定的同位素标记的8-OH-dGuo类似物用作内标,用于通过同位素稀释MS(IDMS)进行定量。结果表明,带有选定离子监测(SIM)的LC / IDMS非常适合于在背景水平和受损DNA中鉴定和定量DNA中的8-OH-dGuo。发现LC / IDMS-SIM的灵敏度水平与以前使用LC串联MS(LC / MS / MS)报道的灵敏度水平相当。结果发现,使用低至2μg的DNA量,每10 6 个DNA碱基大约可检测到五个损伤。结果还表明,该病灶在DNA中的定量水平为每10 6 个DNA碱基一个病灶,或者当使用更多DNA时甚至更低。每次注射最多使用50μgDNA,而不会对测量产生不利影响。在通过酸性水解或通过大肠杆菌Fpg蛋白水解从DNA中去除该化合物后,还使用具有选择离子监测功能的气相色谱/同位素稀释MS(GC / IDMS-SIM)来测量该化合物在DNA中的含量。通过LC / IDMS-SIM和GC / IDMS-SIM获得的背景水平几乎相同。小牛胸腺DNA和从培养的HeLa细胞中分离的DNA用于此目的。这表明就DNA中8-OH-dGuo的测量而言,这两种技术可以提供相似的结果。此外,缓冲水溶液中的DNA被不同辐射剂量的电离辐射破坏,并通过LC / IDMS-SIM和GC / IDMS-SIM进行分析。再次,通过两种技术获得了相似的结果。还检查了GC / MS-SIM对7,8-二氢-8-氧鸟嘌呤的敏感性,发现其远高于LC / MS-SIM的敏感性,并且已报道LC / MS / MS对8-OH-的敏感性dGuo。两者合计,结果明确表明LC / IDMS-SIM非常适合灵敏和准确地测量DNA中的8-OH-dGuo,LC / IDMS-SIM和GC / IDMS-SIM均可提供相似的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号