The purpose of this study was to find out the tensile strength of GMAW welded carbon steel with electric current variation and wire feed rate. The research method used was experimental research with electric current variation of 120 A, 140 A, and 160 A and variation of wire feed rate 4 m/min and 5 m/min. The tensile strength test of sample was done by ASTM E8 / E8M-09 test standard. The result showed that the electric current variation and wire feed rate in welding of carbon steel with GMAW welding gave effect on the value of tensile strength which was varied. The electric current of 120 A and the wire feed rate of 4 m/min obtained the highest tensile strength of 52.67 kgf/mm~(2)and welding with electric current of 120 A and wire feed rate of 5 m/min obtained the lowest tensile strength of 48.33 kgf/mm~(2).
机译:这项研究的目的是找出随电流变化和送丝速度变化的GMAW焊接碳钢的抗拉强度。使用的研究方法是实验研究,电流变化为120 A,140 A和160 A,焊丝进给速度变化为4 m / min和5 m / min。样品的抗拉强度测试是按照ASTM E8 / E8M-09测试标准进行的。结果表明,采用GMAW焊接碳钢时,电流变化和送丝速率对拉伸强度值有影响。 120 A的电流和4 m / min的送丝速度获得最高的抗拉强度52.67 kgf / mm〜(2),而120 A的电流和5 m / min的送丝速度进行焊接的最低抗拉强度为48.33 kgf / mm〜(2)。