Long evacuation time is a key fire safety concern when a supertall building is on fire. The elevator system can be an effective alternative. The performance of a design of fire safe elevator system combining the refuge place with fire safe elevator is studied. An example building based on this proposed design is considered. Smoke spread to the system is studied by the Computational Fluid Dynamics (CFD) code Fire Dynamics Simulator (FDS). Different arrangements of smoke extraction with pressurization systems are evaluated by analysing the smoke dispersion and pressure distributions in this fire safe elevator system. Numerical results were compared with that by theoretical equations. The results show that a smoke extraction system with a four-floor approach pressurization system can be an efficient method for smoke control in elevator system for supertall buildings.
机译:当超高层建筑着火时,疏散时间长是消防安全的关键问题。电梯系统可以是有效的替代方案。研究了避难所与消防电梯相结合的消防电梯系统设计的性能。考虑基于该提议设计的示例建筑。通过计算流体动力学(CFD)代码火灾动力学模拟器(FDS)研究了散布到系统中的烟雾。通过分析此防火电梯系统中的烟气扩散和压力分布,评估了采用增压系统抽烟的不同布置。将数值结果与理论方程进行比较。结果表明,采用四层进场加压系统的排烟系统可以成为超高层建筑电梯系统中排烟的一种有效方法。