The field of office daylighting is vital for both energy efficiency practice and occupants’ visual comfort. With the emergence of green building in Malaysia, building designers are exploring avenues for energy efficiency design; one common strategy is daylighting. The majority literature reviews on daylighting are skewed towards temperate or developed countries, where sky luminous condition is different from that of the Tropics. Conventional daylighting system designs redirect daylight from the envelope or atrium openings, such as light shelves. Presumed to be the pioneer daylight trough in the Tropics, this paper presents the simulated and in-situ lighting level measurements prior to occupancy. This case study presents an as-built daylight trough design which is able to daylight the office space as deep as 6 meters sufficiently. It achieves a lighting power density 1.90W/m2 and saves 39.2% of lighting energy over conventional office lighting energy. Discussed further is the practicality of working with such a system, including cost implication, return on investment and contractual challenges in reaching a consensus on the design. The results reinforce that the effectiveness of daylighting design is very dependable on the sun path and obstacles surrounding the office tower. The RADIANCE simulation correlates well to field measurement results. Further investigation into the light trough, its lighting energy savings, users’ interaction, visual comfort, and glare is still ongoing.
机译:办公室采光领域对于节能实践和居住者的视觉舒适度至关重要。随着马来西亚绿色建筑的兴起,建筑设计师们正在探索节能设计的途径。一种常见的策略是采光。关于采光的大多数文献评论都偏向温带国家或发达国家,因为那里的天空发光条件不同于热带地区。传统的采光系统设计将日光从信封或中庭开口(例如灯架)重定向。假定是热带地区的先驱日光槽,本文介绍了有人居住之前的模拟和现场照明水平测量。本案例研究提出了一种竣工的日光槽设计,该设计能够充分照亮6米深的办公空间。它的照明功率密度为1.90W / m2,比传统的办公室照明能源节省39.2%的照明能源。进一步讨论了使用这种系统的实用性,包括成本问题,投资回报率以及在就设计达成共识时遇到的合同挑战。结果表明,采光设计的有效性非常依赖于阳光路径和办公大楼周围的障碍物。 RADIANCE仿真与现场测量结果紧密相关。灯槽,其照明节能,用户互动,视觉舒适度和眩光的进一步研究仍在进行中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号