首页> 外文期刊>Emerging Infectious Diseases >Performance of 2 Commercial Serologic Tests for Diagnosing Zika Virus Infection
【24h】

Performance of 2 Commercial Serologic Tests for Diagnosing Zika Virus Infection

机译:2种商业血清学检测诊断寨卡病毒感染的性能

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Reliable serologic tests are needed for diagnosis and surveillance of Zika virus infection. We evaluated the Euroimmun and Dia.Pro serologic tests for detection of Zika virus IgM and IgG by using a panel of 199 samples from a region endemic for flaviviruses. Kinetics of Zika virus antibodies were monitored from 300 sequential specimens sampled over a period of 10 months after infection. We observed suboptimal performance; sensitivity for Zika virus IgM was low, especially in the Euroimmun assay (49%), whereas IgM could be detected for months with the Dia.pro assay. The specificity of the Zika virus IgG assays was also low, especially that of Dia.Pro (62%); findings were strongly influenced by the epidemiologic context. These results highlight the complexity of serologic diagnosis of Zika virus infection in regions endemic for flaviviruses. Accurate analysis of the performance of assays is required to adapt and interpret algorithms.
机译:诊断和监测寨卡病毒感染需要可靠的血清学检测。我们通过使用一组来自黄病毒地方性流行地区的199个样品评估了Euroimmun和Dia.Pro血清学检测,以检测寨卡病毒IgM和IgG。从感染后10个月的300个连续样本中监测Zika病毒抗体的动力学。我们观察到性能欠佳; Zika病毒IgM的敏感性较低,尤其是在Euroimmun分析中(49%),而Dia.pro分析可以检测到几个月的IgM。 Zika病毒IgG分析的特异性也很低,尤其是Dia.Pro(62%);研究结果受到流行病学背景的强烈影响。这些结果凸显了黄病毒流行地区的寨卡病毒感染血清学诊断的复杂性。需要对分析性能进行准确的分析,以适应和解释算法。