This paper compares two methods applied to measure surface temperatures at an experimental setup designed to analyse flow boiling heat transfer. The temperature measurements were performed in two parallel rectangular minichannels, both 1.7 mm deep, 16 mm wide and 180 mm long. The heating element for the fluid flowing in each minichannel was a thin foil made of Haynes-230. The two measurement methods employed to determine the surface temperature of the foil were: the contact method, which involved mounting thermocouples at several points in one minichannel, and the contactless method to study the other minichannel, where the results were provided with an infrared camera. Calculations were necessary to compare the temperature results. Two sets of measurement data obtained for different values of the heat flux were analysed using the basic statistical methods, the method error and the method accuracy. The experimental error and the method accuracy were taken into account. The comparative analysis showed that although the values and distributions of the surface temperatures obtained with the two methods were similar but both methods had certain limitations.
机译:本文比较了在设计用于分析沸腾传热的实验装置上测量表面温度的两种方法。温度测量是在两个平行的矩形微型通道中进行的,分别为1.7毫米深,16毫米宽和180毫米长。在每个小通道中流动的流体的加热元件是由Haynes-230制成的薄箔。用来确定箔片表面温度的两种测量方法是:接触法,涉及在一个小通道的几个点上安装热电偶;非接触法研究另一个小通道,用红外摄像机提供结果。必须进行计算以比较温度结果。使用基本统计方法,方法误差和方法准确性,分析了针对不同热通量值获得的两组测量数据。考虑了实验误差和方法准确性。对比分析表明,尽管两种方法获得的表面温度值和分布相似,但两种方法都有一定的局限性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号