Photoreceptor Layer Thickness Changes During Dark Adaptation Observed With Ultrahigh-Resolution Optical Coherence Tomography

机译:超高分辨率光学相干层析成像技术在暗适应过程中感光层厚度变化。

获取原文
           

摘要

Purpose: To examine outer retinal band changes after flash stimulus and subsequent dark adaptation with ultrahigh-resolution optical coherence tomography (UHR-OCT). Methods: Five dark-adapted left eyes of five normal subjects were imaged with 3-??m axial-resolution UHR-OCT during 30 minutes of dark adaptation following 96%, 54%, 23%, and 0% full-field and 54% half-field rhodopsin bleach. We identified the ellipsoid zone inner segment/outer segment (EZ[IS/OS]), cone interdigitation zone (CIZ), rod interdigitation zone (RIZ), retinal pigment epithelium (RPE), and Bruch's membrane (BM) axial positions and generated two-dimensional thickness maps of the EZ(IS/OS) to the four bands. The average thickness over an area of the thickness map was compared against that of the dark-adapted baselines. The time-dependent thickness changes (photoresponses) were statistically compared against 0% bleach. Dark adaptometry was performed with the same bleaching protocol. Results: The EZ(IS/OS)-CIZ photoresponse was significantly different at 96% (P 0.0001) and 54% (P = 0.006) bleach. At all three bleaching levels, the EZ(IS/OS)-RIZ, -RPE, and -BM responses were significantly different (P 0.0001). The EZ(IS/OS)-CIZ and EZ(IS/OS)-RIZ time courses were similar to the recovery of rod- and cone-mediated sensitivity, respectively, measured with dark adaptometry. The maximal EZ(IS/OS)-CIZ and EZ(IS/OS)-RIZ response magnitudes doubled from 54% to 96% bleach. Both EZ(IS/OS)-RPE and EZ(IS/OS)-BM responses resembled dampened oscillations that were graded in amplitude and duration with bleaching intensity. Half-field photoresponses were localized to the stimulated retina. Conclusions: With noninvasive, near-infrared UHR-OCT, we characterized three distinct, spatially localized photoresponses in the outer retinal bands. These photoresponses have potential value as physical correlates of photoreceptor function.
机译:目的:通过超高分辨率光学相干断层扫描(UHR-OCT)检查闪光刺激和随后的暗适应后视网膜外带的变化。方法:在96%,54%,23%和0%的全视场和54%的黑暗适应后30分钟内,对3名正常受试者的5只适应黑暗的左眼进行3 ?? m轴向分辨率UHR-OCT成像%半视紫红质漂白剂。我们确定了椭球区的内部节段/外部节段(EZ [IS / OS]),圆锥交叉区(CIZ),杆交叉区(RIZ),视网膜色素上皮(RPE)和Bruch膜(BM)轴向位置并生成了EZ(IS / OS)到四个波段的二维厚度图。将厚度图区域上的平均厚度与暗适应基线的平均厚度进行比较。随时间变化的厚度变化(光响应)与0%漂白剂进行了统计比较。用相同的漂白方案进行暗适应。结果:EZ(IS / OS)-CIZ光响应在96%(P <0.0001)和54%(P = 0.006)漂白剂下显着不同。在所有三个漂白水平下,EZ(IS / OS)-RIZ,-RPE和-BM响应均显着不同(P <0.0001)。 EZ(IS / OS)-CIZ和EZ(IS / OS)-RIZ时程分别类似于暗适应法测得的杆和锥介导的灵敏度的恢复。 EZ(IS / OS)-CIZ和EZ(IS / OS)-RIZ的最大响应幅度从54%漂白到96%漂白倍增。 EZ(IS / OS)-RPE和EZ(IS / OS)-BM响应都类似于衰减的振荡,衰减的幅度和持续时间随漂白强度而变化。半场光响应被定位在受刺激的视网膜上。结论:利用无创,近红外UHR-OCT,我们在视网膜外带中表征了三种不同的,空间定位的光响应。这些光响应具有作为光感受器功能的物理关联的潜在值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号