...
首页> 外文期刊>Investigative ophthalmology & visual science >Quantitative Evaluation of Phase Retardation in Filtering Blebs Using Polarization-Sensitive Optical Coherence Tomography
【24h】

Quantitative Evaluation of Phase Retardation in Filtering Blebs Using Polarization-Sensitive Optical Coherence Tomography

机译:偏振敏感光学相干断层扫描技术定量评估滤泡中的相位延迟

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Purpose: Polarization-sensitive optical coherence tomography (PS-OCT) can detect and evaluate scar fibrosis of the filtering blebs after glaucoma surgery. Although the change in phase retardation reportedly reflects bleb function, quantitative assessment of phase retardation in ocular tissues has not been conducted. We aimed to establish quantitative methods to investigate changes in phase retardation in the blebs after surgery using PS-OCT. Methods: Twenty-two blebs of 22 patients who had undergone glaucoma filtration surgery were consecutively examined for 4 months. Phase retardation was measured by PS-OCT and quantitatively analyzed to evaluate its relationship with bleb function based on intraocular pressure and medication use. Cross-sectional re-evaluation was also performed for a previous data set of 153 blebs of 122 patients. Results: In consecutive measurements, all blebs showed a low phase retardation value and good bleb function until 2 weeks. One month postoperatively, the phase retardation value was significantly increased, whereas bleb function was still good. The phase retardation value at 1 month postoperatively was significantly correlated with bleb function at 4 months postoperatively. While 55.6% of blebs with a high phase retardation value at 1 month subsequently lost function, only 7.7% with a low phase retardation value had bleb failure. In the cross-sectional re-evaluation, the quantitatively evaluated phase retardation value was highly correlated with bleb function (?2 = 0.770, P 0.001). Conclusions: An increase in phase retardation preceded deterioration of bleb function. The change in phase retardation may provide a prognostic metric for bleb function in the early stage after surgery.
机译:目的:偏振敏感光学相干断层扫描(PS-OCT)可以检测和评估青光眼手术后滤过泡的瘢痕纤维化。虽然据报道相延迟的变化反映了起泡功能,但是尚未进行眼组织中相延迟的定量评估。我们旨在建立定量方法,以研究使用PS-OCT手术后小泡中相位延迟的变化。方法:对22例接受青光眼滤过手术的患者中的22例患者进行连续检查,共4个月。通过PS-OCT测量相位延迟,并根据眼内压和药物使用情况进行定量分析,以评估其与起泡功能的关系。还对122位患者的153个气泡的先前数据集进行了横断面重新评估。结果:在连续的测量中,直到2周,所有气泡均显示出低相位延迟值和良好的气泡功能。术后一个月,相位延迟值显着增加,而起泡功能仍然良好。术后1个月的相位延迟值与术后4个月的起泡功能显着相关。虽然有15.6个月时相位延迟值高的气泡中有55.6%随后失去了功能,但只有7.7%时相延迟值较低的气泡中有气泡失效。在截面再评价中,定量评价的相位延迟值与起泡函数高度相关(Δ2= 0.770,P <0.001)。结论:相位延迟增加先于起泡功能恶化。相位延迟的变化可为术后早期的起泡功能提供预后指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号