Retinal Vascular Measurements Using Automated Fundus Image Analysis: The Effect of Hypertension on Vascular Caliber in Adult Population

机译:使用自动眼底图像分析进行视网膜血管测量:高血压对成人口径的影响

获取原文
           

摘要

?Purpose?To implement an automated fundus image analysis in order to determine the effects of hypertension (HTN) on the measurement of retinal arteriole and venule caliber. ?Methods?This is a retrospective study of 1,481 adults in an executive health screening program. All clinical data was collected from 2007-2009. Nonmydriatic retinal images were obtained during screening examinations using the Topcon NW6s digital camera. Automated measurements of vascular caliber were generated from retinal images using a validated algorithm. Retinal arteriole caliber and venule caliber were compared between normotensive and hypertensive patients and correlated to the systolic and diastolic blood pressure. ?Results?The 1,481 patients enrolled were divided to two groups: normotensive (82.3%) and hypertensive (17.7%). The mean age was 53 ± 9.5 years (mean ± SD) 80% were male, 79% were Caucasian and 21% were African Americans, Hispanic, Latin, and Asian. Both groups were similar in demographics, while only the hypertensive group was treated with antihypertensive medications. There was significant difference in the mean systolic and diastolic blood pressure between the groups; in the normotensive group (n=1,218) the mean pressures were 123mmHg ± 13.3 and 75mmHg ± 8.7 respectively, and in the hypertensive group (n=263) the mean pressures were 135mmHg ± 15.6 and 81mmHg ± 9.6 respectively (p0.001). Furthermore, group differences were also found in the arterial caliber and venule caliber (p0.0001), and arterial-venous ratio (AVR) (p= 0.04). In the normotensive group, systolic blood pressure (SBP) was negatively correlated to the arterial and venule caliber (r= -0.192, p0.0001; r= -0.102; p0.001, respectively). However, this correlation was not present in the hypertensive group (p0.4). In confirmation with previous studies, there was a significant difference between the right and left eyes with regards to total arteriole area (p0.0001), total venule area (p0.0001), and AVR (p0.0001), independent of diagnosis of HTN. ?Conclusions?This study demonstrates the successful implementation of automated measurements of metrics, such as arteriole and venule caliber, in detecting hypertensive changes in the retina vasculature. These results suggest that automated measurements of nonmydriatic retinal images may be used to supplement the diagnosis of systemic hypertension. ? Keywords: 550 imaging/image analysis: clinical ? 549 image processing ? 688 retina ?.
机译:目的:实施自动眼底图像分析,以确定高血压(HTN)对视网膜小动脉和小静脉口径测量的影响。方法:这是一项对执行健康检查程序中的1,481名成年人的回顾性研究。所有临床数据均收集自2007-2009年。使用Topcon NW6s数码相机在筛查过程中获得了非散瞳的视网膜图像。使用经过验证的算法,从视网膜图像生成血管口径的自动测量值。在血压正常和高血压患者中比较了视网膜小动脉口径和小静脉口径,并与收缩压和舒张压相关。结果:1481名患者被分为两组:血压正常(82.3%)和高血压(17.7%)。平均年龄为53±9.5岁(平均数±SD),男性80%,白种人79%,非裔美国人,西班牙裔,拉丁裔和亚洲裔21%。两组在人口统计学上相似,而只有高血压组接受过降压药治疗。两组之间的平均收缩压和舒张压之间存在显着差异。血压正常组(n = 1,218)的平均压力分别为123mmHg±13.3和75mmHg±8.7,而高血压组(n = 263)的平均压力分别为135mmHg±15.6和81mmHg±9.6(p <0.001)。此外,在动脉口径和小静脉口径(p <0.0001)和动静脉比(AVR)(p = 0.04)中也发现了组差异。在血压正常组中,收缩压(SBP)与动脉和小静脉口径呈负相关(r = -0.192,p <0.0001; r ​​= -0.102; p <0.001)。但是,这种相关性在高血压组中不存在(p> 0.4)。与先前的研究证实,在右眼和左眼之间,在总小动脉面积(p <0.0001),总小静脉面积(p <0.0001)和AVR(p <0.0001)方面存在显着差异,与诊断HTN。结论本研究表明,在检测视网膜脉管系统中的高血压变化方面,成功实现了指标(例如小动脉和小静脉口径)的自动测量。这些结果表明非散瞳视网膜图像的自动测量可用于补充系统性高血压的诊断。 ?关键字:550成像/图像分析:临床549图像处理? 688视网膜?

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号