High-speed 1-??m Jones-matrix Multi-contrast Optical Coherence Tomography for Simultaneous 3D Doppler and Polarization Imaging

机译:高速1?m琼斯矩阵多对比度光学相干层析成像,用于同时进行3D多普勒和偏振成像

获取原文

摘要

?Purpose?In order to enhance the clinical utility of 1-μm Jones-matrix multi-contrast optical coherence tomography (MC-OCT), A-scan rate has been increased to 200,000 A-lines/s, which was previously 100,000 A-lines/s. This study aims at evaluating the simultaneous 3D Doppler and polarization imaging ability at the doubled high speed. ?Methods?High-speed MC-OCT is capable of full Jones matrix measurement of in vivo human eye. The system does not use active polarization components and based on commercially available 100 KHz wavelength sweeping laser, and hence it is stable. The A-line rate is doubled into 200,000 A-lines by using optical buffering technology. By analyzing the measured Jones matrix tomography, scattering OCT, polarization sensitive images (phase retardation and degree-of-polarization-uniformity (DOPU)) and high-sensitive flow image are obtained. 6 mm × 6 mm areas around macula and optic nerve head (ONH) were scanned with 512 A-scans × 256 B-scans × 4 repeated-scans/B-scan in 3.3 s. The depth resolution was 10.6 μm in tissue. 8 eyes of 4 subjects without marked posterior disorder were measured to evaluate the utility of the MC-OCT. ?Results?High-speed MC-OCT gives similar contrast with the images obtained in a previous study with 100,000 A-line/s MC-OCT (Ju, Hong et al., ARVO 2013) even with a reduced measurement time. Figure 1 shows a representative case of myopic eye. In OCT intensity en face projection (a) and cross-section (c), myopic conus appeared with hyper-scattering in 4 of 4 myopic eyes. Choroidal vasculature was observed from power Doppler projection (b) in 8 of 8 eyes. In a phase retardation image (e), lamina cribrosa was identified at the ONH (8 of 8 eyes). RPE layer is identified with a DOPU image (e) as low DOPU line (8 of 8 eyes). By utilizing high-speed A-scan rate, the occurrence of eye motion during the measurement was reduced. Among 16 measurements of 4 subjects, the mean occurrence of quick motion was 1.5 times/volume as exemplified by the red arrow in Fig. 1b, while it was 4.4 times/volume with the data in the previous study with the 100,000 A-lines/s system (20 measurements of 5 subjects, ARVO 2013). ?Conclusions?High-speed MC-OCT demonstrated simultaneous structure, flow and RPE-contrast imaging. The reduced measurement time might enhance the clinical utility of MC-OCT with less motion artifact. ?View OriginalDownload SlideView OriginalDownload Slide? Keywords: 552 imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound) ? 549 image processing ?.
机译:目的:为了增强1-μm琼斯矩阵多对比度光学相干断层扫描(MC-OCT)的临床效用,A扫描速率已提高至200,000 A-lines / s,之前为100,000 A-行/秒这项研究旨在评估双倍高速下的同时3D多普勒和偏振成像能力。方法高速MC-OCT能够对体内人眼进行完整的Jones矩阵测量。该系统不使用有源偏振组件,而是基于市售的100 KHz波长扫描激光器,因此非常稳定。通过使用光学缓冲技术,A线速率将翻倍至200,000条A线。通过分析测得的琼斯矩阵层析成像,散射OCT,偏振敏感图像(相位延迟和偏振均匀度(DOPU))和高敏感度流动图像。用512 A扫描×256 B扫描×4重复扫描/ B扫描在3.3 s内扫描黄斑和视神经头(ONH)周围6 mm×6 mm区域。组织中的深度分辨率为10.6μm。测量了4名无明显后验障碍的受试者的8只眼,以评估MC-OCT的实用性。结果:高速MC-OCT与先前使用100,000 A-line / s MC-OCT的研究(Ju,Hong等,ARVO 2013)获得的图像具有相似的对比度,即使测量时间减少了。图1显示了近视眼的典型案例。在OCT强度面对面投影(a)和横截面(c)中,近视圆锥在四只近视眼中的四只中以高度散射的形式出现。从功率多普勒投影(b)中的8只眼中观察到脉络膜脉管系统。在相位延迟图像(e)中,在ONH(8眼中的8眼)处发现了筛状薄板。用DOPU图像(e)将RPE层标识为低DOPU线(8眼中的8眼)。通过使用高速A扫描速率,可以减少测量过程中眼睛运动的发生。在对4位受试者进行的16次测量中,快动作的平均发生率为1.5倍/体积,如图1b中的红色箭头所示,而根据先前研究的100,000条A-线/倍,其平均发生率为4.4倍/体积。 s系统(5个主题的20个测量值,ARVO 2013)。结论:高速MC-OCT展示了同时的结构,流动和RPE对比成像。减少的测量时间可能会以较少的运动伪影增强MC-OCT的临床实用性。查看原始下载幻灯片查看原始下载幻灯片?关键字:552种成像方法(CT,FA,ICG,MRI,OCT,RTA,SLO,超声)? 549图像处理?

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号