首页> 外文期刊>Investigative ophthalmology & visual science >24-Hour Intraocular Pressure of Young Healthy Humans in Supine Position: Rhythm and Reproducibility
【24h】

24-Hour Intraocular Pressure of Young Healthy Humans in Supine Position: Rhythm and Reproducibility

机译:仰卧位的年轻健康人的24小时眼压:节律和可重复性

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Purpose.: We evaluated the supine 24-hour IOP rhythm reproducibility over 6 weeks in healthy humans. Methods.: Six healthy young male subjects underwent six 24-hour sessions of IOP measurements over a 6-week period. Subjects were housed in a sleep laboratory in a constant controlled supine position and in a strictly controlled environment. IOP was measured hourly using a pneumatonometer. A nonlinear least-squares dual harmonic regression analysis was used to model the 24-hour IOP rhythm. The intra- and intersubject variability of acrophase, bathyphase, amplitude, and IOP values were evaluated. Results.: A significant nyctohemeral IOP rhythm was noted in 30 of 36 (83%) sessions. Mean nocturnal IOP was significantly higher than diurnal IOP (20.1 ?± 0.2 mm Hg [SD] vs. 18.8 ?± 0.1 mm Hg, P 0.001) in all subjects. Amplitudes were not statistically different among subjects (P = 0.52). In contrast, acrophase and bathyphase were statistically different (P 0.05). Intrasubject homogeneity of distribution over time of the acrophase and bathyphase was significant in 3 of 6 and 4 of 6 subjects, respectively. Intraclass correlation coefficients of midline estimating statistic of rhythm (MESOR) and IOP values at 2:00, 3:00, 4:00, 10:00, and 11:00 AM, and 2:00 PM showed fair to good agreement among sessions. Conclusions.: In a constant supine position, all subjects exhibited a nyctohemeral IOP rhythm present at an average rate of 80% of all sessions. With the currently available methods of tonometry, intrasubject reproducibility of rhythmic parameters and IOP values is limited. IOP values in the morning and IOP MESOR were the most reproducible parameters among the six visits.
机译:目的:我们评估了健康人在6周内仰卧24小时IOP节律的可重复性。方法:6名健康的年轻男性受试者在6周的时间内进行了6次24小时的IOP测量。将受试者以恒定控制的仰卧位和严格控制的环境安置在睡眠实验室中。使用气压计每小时测量IOP。非线性最小二乘双重谐波回归分析用于模拟24小时IOP节奏。评估了顶生相,水生相,振幅和IOP值的受试者内和受试者间变异性。结果:在36个疗程中的30个疗程(83%)中观察到了明显的夜尿IOP节律。在所有受试者中,平均夜间IOP均高于昼夜IOP(20.1±0.2 mm Hg [SD]与18.8±0.1 mm Hg,P <0.001)。受试者之间的振幅无统计学差异(P = 0.52)。相反,顶生相和水生相有统计学差异(P <0.05)。在6个受试者中有6个中的3个和6个受试者中的4个分别在顶体期和水生期的受试者体内分布的同质性显着。在2:00、3:00、4:00、10:00和11:00 AM和2:00 PM的节律中值(MESOR)和IOP值的中线估计统计量的类内相关系数显示会话之间的一致性良好。结论:在恒定的仰卧姿势下,所有受试者均表现出夜间眼部IOP节律,平均比率为所有疗程的80%。使用当前可用的眼压测量方法,节律参数和IOP值在受试者内的再现性受到限制。在六次访问中,早上的IOP值和IOP MESOR是可重复的参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号