Comparative Analysis of PCR–Electrospray Ionization/Mass Spectrometry (MS) and MALDI-TOF/MS for the Identification of Bacteria and Yeast from Positive Blood Culture Bottles

机译:PCR-电喷雾电离/质谱(MS)和MALDI-TOF / MS的比较分析,用于从阳性血培养瓶中鉴定细菌和酵母

获取原文
       

摘要

BACKGROUND: Emerging technologies for rapid identification of microbes demonstrate a shift from traditional biochemical and molecular testing algorithms toward methods using mass spectrometry (MS) for the semiquantitative analysis of microbial proteins and genetic elements. This study was performed to assess the diagnostic accuracy of 2 such technologies, PCR–electrospray ionization (ESI)/MS and MALDI-TOF/MS, with respect to phenotypic and biochemical profiling as a reference standard method. A positive challenge set of blood culture bottles was used to compare PCR-ESI/MS and MALDI-TOF/MS performance on a matched set of samples.METHODS: We performed characterization of bloodstream infections from blood cultures using the Ibis T5000 PCR-ESI/MS and the Bruker MALDI Biotyper 2.0 (MALDI-TOF/MS) platforms for microbial identification. Diagnostic accuracy was determined by independent comparison of each method to phenotypic and biochemical characterization with Vitek2 analysis as the reference standard identification.RESULTS: The diagnostic accuracy, represented as positive agreement, at the genus level was 0.965 (0.930–0.984) for PCR-ESI/MS and 0.969 (0.935–0.987) for MALDI-TOF/MS, and at the species level was 0.952 (0.912–0.974) with PCR-ESI/MS and 0.943 (0.902–0.968) for MALDI-TOF/MS. No statistically significant difference was found between PCR-ESI/MS and MALDI-TOF/MS in the ability to rapidly identify microorganisms isolated from blood culture.CONCLUSIONS: Our results demonstrate that PCR-ESI/MS and MALDI-TOF/MS are equivalent in their ability to characterize bloodstream infections with respect to the reference standard, and highlight key differences in the methods that allow for each method to have a unique niche as a tool for rapid identification of microbes in blood cultures.
机译:背景:用于快速鉴定微生物的新兴技术证明了从传统的生化和分子测试算法向使用质谱(MS)进行微生物蛋白质和遗传元素半定量分析的方法的转变。这项研究的目的是评估两种技术的诊断准确性,即PCR-电喷雾电离(ESI)/ MS和MALDI-TOF / MS,以表型和生化分析为参考标准方法。使用一组阳性挑战的血培养瓶来比较一组匹配样品上的PCR-ESI / MS和MALDI-TOF / MS性能。方法:我们使用Ibis T5000 PCR-ESI /对来自血培养的血流感染进行了表征MS和用于微生物鉴定的布鲁克MALDI Biotyper 2.0(MALDI-TOF / MS)平台。通过将每种方法与表型和生化特征进行独立比较,并以Vitek2分析作为参考标准,确定诊断准确性。结果:PCR-ESI在属水平的诊断准确性为0.965(0.930–0.984),表示为阳性。 / MS和MALDI-TOF / MS分别为0.969(0.935-0.987)和PCR-ESI / MS在物种水平上为0.952(0.912-0.974)和MALDI-TOF / MS为0.943(0.902-0.968)。快速鉴定从血液培养物中分离出的微生物的能力在PCR-ESI / MS和MALDI-TOF / MS之间没有统计学上的显着差异。结论:我们的结果表明,PCR-ESI / MS和MALDI-TOF / MS在相对于参考标准,它们具有表征血流感染的能力,并突出了方法的关键差异,使每种方法都有独特的优势,可以作为快速鉴定血液培养物中微生物的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号