Background: Myeloperoxidase (MPO) has shown potential as a marker for cardiovascular disease. Limited studies have been published with a variety of sample types, resulting in a wide range of MPO values. Little is known or understood about the impact of collection tube type and preanalytical handling of specimens for MPO determination.Method: MPO concentration was determined by use of the ARCHITECT? MPO research use assay, which is currently under development. Samples were collected into multiple anticoagulant collection tubes from donors and patients presenting to the emergency department with symptoms of acute coronary syndromes. Whole blood was stored on ice or at room temperature for predetermined time periods. We also evaluated serum and plasma after centrifugation followed by storage at room temperature, 2–8 °C, and below ?10 °C.Results: Baseline sample concentrations were dependent on collection tube type as well as handling conditions. MPO concentrations were consistently higher in samples collected in serum and heparin plasma tubes than in samples in EDTA or citrate tubes. Spike recovery was acceptable in all sera and plasma tested, indicating that the increased MPO concentrations were not due directly to an anticoagulant interference.Conclusions: The collection tube type and preanalytical handling are critical for accurate and consistent MPO measurement. The preferred anticoagulant and tubes are the EDTA or EDTA plasma preparation tube. MPO concentrations in samples collected in these tubes are stable before centrifugation as whole blood as well as plasma after processing.
机译:背景:髓过氧化物酶(MPO)已显示出潜在的心血管疾病标志物。已经发表了有关各种样品类型的有限研究,从而产生了广泛的MPO值。关于收集管类型和样品的分析前处理对MPO测定的影响知之甚少或了解。方法:使用ARCHITECT测定MPO浓度? MPO研究使用测定法,目前正在开发中。从供者和急诊科出现急性冠状动脉综合征症状的患者中,将样品收集到多个抗凝剂收集管中。将全血在冰上或室温下保存预定的时间。我们还评估了离心后的血清和血浆,然后在室温,2–8°C和低于?10°C的温度下保存。结果:基线样品浓度取决于收集管的类型以及处理条件。血清和肝素血浆试管中收集的样品中的MPO浓度始终高于EDTA或柠檬酸盐试管中的样品。峰值恢复在所有测试的血清和血浆中都是可以接受的,这表明MPO浓度的增加并不是直接由于抗凝干扰引起的。结论:收集管的类型和分析前的处理对于准确一致地进行MPO测量至关重要。优选的抗凝剂和试管是EDTA或EDTA血浆制备管。在离心之前,这些管中收集的样品中的MPO浓度是稳定的,全血以及处理后的血浆也是如此。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号