BACKGROUND: The Japanese Committee for Clinical Laboratory Standards (JCCLS) has developed a multianalyte conventional reference material (MacRM) for nationwide standardization of laboratory measurements.METHODS: To prepare the MacRM, pooled sera were obtained from healthy Japanese individuals. Target values of the pooled sera for 30 analytes were assigned on the basis of the measurement results of 45 certified clinical laboratories whose calibration was verified by measuring certified reference materials (CRMs) provided by the National Institute of Standards and Technology, the Institute for Reference Materials and Measurements, and JCCLS. Commutability of MacRM was assessed by comparison with results for 150 individual inpatients at Fukuoka University Chikushi Hospital. Survey samples were prepared by essentially the same method for MacRM but without target values. The survey samples were used to assess agreement among 165 laboratories that used various assay kits and platforms calibrated with the MacRM.RESULTS: The commutability of MacRM was confirmed for 30 analytes with sera from 150 individual patients. The imprecision (CV) of measurements of survey samples (high and low concentrations) among the 165 laboratories was 0.4%–10.0%. Twenty-six of 30 analytes were within the goals for interinstitutional allowable bias. An aliquot of MacRM stored frozen at ?80 °C remained stable for ≥4 years.CONCLUSIONS: The MacRM was successfully applied as a calibrator to achieve nationwide standardization for 30 analytes measured by 165 laboratories that used various methods from different manufacturers.
机译:背景:日本临床实验室标准委员会(JCCLS)已开发出一种多分析物的常规参考材料(MacRM),用于全国范围内实验室测量的标准化。方法:为制备MacRM,从健康的日本人那里获得了混合血清。根据45个经过认证的临床实验室的测量结果指定30种分析物的合并血清的目标值,这些实验室的校准通过测量由美国国家标准技术研究院,标准物质研究所提供的认证参考物质(CRM)进行验证和测量,以及JCCLS。通过与福冈大学筑紫医院的150例住院患者的结果进行比较,评估了MacRM的可交换性。通过与MacRM基本相同的方法制备调查样本,但没有目标值。调查样本用于评估165个实验室的一致性,这些实验室使用了各种用MacRM校准的检测试剂盒和平台。结果:确认了150名患者血清中30种分析物与MacRM的可交换性。 165个实验室中测量样本(高浓度和低浓度)的测量不精确度(CV)为0.4%–10.0%。 30种分析物中的26种在机构间容许偏差的目标之内。结论:MacRM的等分试样冷冻保存在80°C时可保持稳定≥4年。结论:MacRM成功地用作校准品,实现了165个实验室使用不同制造商的各种方法测量的30种分析物的全国标准化。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号