首页> 外文期刊>Clinical Chemistry: Journal of the American Association for Clinical Chemists >Effects of Nine Hemoglobin Variants on Five Glycohemoglobin Methods
【24h】

Effects of Nine Hemoglobin Variants on Five Glycohemoglobin Methods

机译:九种血红蛋白变异体对五种糖化血红蛋白方法的影响

获取原文
获取外文期刊封面目录资料

摘要

Most studies of the effects of variant hemoglobins (Hbs) on specific glycohemoglobin (gHb) methods have been case reports of a single variant Hb and one or two analytical methods (1)(2)(3)(4). Few studies have systematically examined multiple Hb variants with several widely used analytical methods. In this report, we describe the effects of nine heterozygous Hb variants on five gHb methods. A boronate affinity method was chosen as the comparative method because it has high specificity for glycated Hb and negligible interference by variant Hbs (5).Over 10 months, we studied 40 samples with nine variant Hbs; 38 were detected during routine gHb analysis by a cation-exchange method. Two samples (Hb E trait) were identified during routine Hb phenotype analysis. Samples were stored at 2–8 °C until analysis within 10 days of collection.Cation-exchange chromatography was performed on a Variant system with the Hb A1c program (Bio-Rad Laboratories) and on an A1c 2.2 Plus analyzer using a 3-min protocol (Tosoh Medics). Immunoassays were performed on a DCA 2000 (Bayer Corporation, Elkhart, IN) and on a Hitachi 717 with Tina-quant HbA1c II reagents (Roche Diagnostics, Indianapolis, IN). Boronate affinity analysis on a CLC 385 analyzer (Primus Corporation) served as the comparative method. All methods used the manufacturers’ reagents as recommended, had imprecision (CV) 5%, are certified traceable to the Diabetes Control and Complications Trial by the National Glycohemoglobin Standardization Program, and reported results as percentage of Hb A1c.Hb phenotype analysis was performed on all samples using a PVS99 system (Primus). This HPLC system uses a poly-aspartic acid cation-exchange column and a complex nonlinear salt and pH gradient at 40 °C. Rare phenotypes, including Grady, Hope, and Raleigh were identified using a poly-aspartic acid column with a nonlinear salt and pH gradient …
机译:大多数关于变异血红蛋白(Hbs)对特定糖化血红蛋白(gHb)方法影响的研究都是单个变异Hb和一种或两种分析方法的案例报道(1)(2)(3)(4)。很少有研究使用几种广泛使用的分析方法来系统地检查多种Hb变异体。在本报告中,我们描述了9种杂合Hb变体对5种gHb方法的影响。选择硼酸亲和法作为比较方法是因为它对糖化Hb的特异性高,并且对变体Hb的干扰可忽略不计(5)。在10个月的时间里,我们研究了40个样品,其中有9个变体Hb。在常规的gHb分析中,通过阳离子交换法检测到38种。在常规Hb表型分析中鉴定了两个样品(Hb E性状)。样品保存在2–8°C直至收集后10天内进行分析。阳离子交换色谱法是使用Hb A1c程序(Bio-Rad Laboratories)在Variant系统上和3分钟内在A1c 2.2 Plus分析仪上进行的协议(Tosoh Medics)。免疫测定是在DCA 2000(拜耳公司,印第安纳州埃尔克哈特)和日立717上使用Tina定量HbA1c II试剂(罗氏诊断公司,印第安纳波利斯,印第安纳州)进行的。在CLC 385分析仪(Primus Corporation)上的硼酸酯亲和力分析用作比较方法。所有使用推荐使用制造商试剂的方法,不精确度(CV)<5%,均已通过美国糖化血红蛋白标准化计划认证可追溯至糖尿病控制和并发症试验,并以Hb A1c的百分比报告结果。进行了Hb表型分析使用PVS99系统(Primus)对所有样品进行分析。该HPLC系统使用聚天冬氨酸阳离子交换柱以及在40°C下复杂的非线性盐和pH梯度。使用具有非线性盐和pH梯度的聚天冬氨酸色谱柱,鉴定了包括Grady,Hope和Raleigh在内的罕见表型……

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号