Analytical performance evaluation of EMIT II monoclonal amphetamine/methamphetamine assay: more specificity than EMIT d.a.u. monoclonal amphetamine/methamphetamine assay.

机译:EMIT II单克隆苯丙胺/甲基苯丙胺测定的分析性能评估:比EMIT d.a.u更具特异性。单克隆苯丙胺/甲基苯丙胺测定。

获取原文
   

获取外文期刊封面封底 >>

       

摘要

We evaluated a new EMIT II monoclonal amphetamine/methamphetamine assay for screening human urine by comparing it with the EMIT d.a.u. monoclonal amphetamine/methamphetamine assay and a fluorescence polarization assay. The EMIT II assay has a cutoff of 1 mg/L d-methamphetamine. The EMIT II and EMIT d.a.u. assays were run on a BM/Hitachi 704 analyzer; for the fluorescence polarization assay we used a TDx analyzer. All EMIT II positive samples were also analyzed by the fluorescence polarization assay. We used gas chromatography/mass spectrometry (GC/MS) for confirmation of the presence of amphetamine or methamphetamine. Within-run CVs for the Level 1 (1 mg/L) and Level 2 (3 mg/L) calibrators for the EMIT II assay were 0.47% and 0.53%, respectively. Corresponding between-run CVs were 1.48% and 1.60%, respectively. Of the 1007 samples screened for amphetamines, 50 were positive by the EMIT d.a.u. assay; 21 samples (not a subset of the 50 samples) were positive by the EMIT II assay. However, 19 samples that tested positive by EMIT II also tested positive by the EMIT d.a.u. assay. Subsequent testing of the EMIT II positive samples by the fluorescence polarization assay detected in six positive samples. By means of chiral derivatization wer identified two specimens containing primarily l-isomers of amphetamine and methamphetamine. Sympathomimetic amines were identified in several of the samples not containing amphetamine or methamphetamine.
机译:我们通过与EMIT d.a.u进行比较,评估了一种新的EMIT II单克隆苯丙胺/甲基苯丙胺测定法,用于筛查人的尿液。单克隆苯丙胺/甲基苯丙胺测定法和荧光偏振测定法。 EMIT II分析的临界值为1 mg / L d-甲基苯丙胺。 EMIT II和EMIT d.a.u.在BM / Hitachi 704分析仪上进行测定;对于荧光偏振测定,我们使用了TDx分析仪。还通过荧光偏振分析法分析了所有EMIT II阳性样品。我们使用气相色谱/质谱(GC / MS)确认苯丙胺或甲基苯丙胺的存在。用于EMIT II分析的1级(1 mg / L)和2级(3 mg / L)校准品的批内CV分别为0.47%和0.53%。两次运行之间的对应CV分别为1.48%和1.60%。在EMIT d.a.u筛选的1007个苯丙胺样品中,有50个呈阳性。化验通过EMIT II分析,有21个样品(不是50个样品的子集)为阳性。但是,通过EMIT II测试呈阳性的19个样品也通过EMIT d.a.u测试呈阳性。分析。随后通过在六个阳性样品中检测到的荧光偏振测定法对EMIT II阳性样品进行测试。通过手性衍生法,我们鉴定出两个主要含有苯丙胺和甲基苯丙胺的l-异构体的样品。在一些不含苯丙胺或甲基苯丙胺的样品中鉴定出拟交感神经胺。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号