We studied and compared results of two urine dip-stick procedures for protein with those of quantitative measurements of total protein and albumin in urine. Sensitivity, specificity, and predictive value of "normal" and "abnormal" dip-stick results, assay efficiency, technologist precision, and method association were determined. Precision was poor, attributable largely to variation within each technologist. Relative to a defined measure of precision, technologist performance appears to be uniform within each product. Patients' urinary protein concentrations of less than 200 mg/liter can be distinguished from concentrations greater than 3000 mg/liter with confidence by dip-stick procedures. Urin samples with low albumin/total protein ratios were frequently falsely negative by dip-stick assays.
机译:我们研究并比较了两种尿液试纸法对蛋白质的测量结果与定量测定尿液中总蛋白和白蛋白的结果。确定了“正常”和“异常”量油尺结果的灵敏度,特异性和预测值,测定效率,技术人员的精密度和方法的关联性。精度很差,主要归因于每个技术人员的差异。相对于定义的精度度量,技术人员在每种产品中的性能似乎是一致的。患者的尿蛋白浓度低于200毫克/升可以通过量油尺程序有把握地与浓度高于3000毫克/升进行区分。低白蛋白/总蛋白比率低的尿素样品通常通过浸入-棒试验被假阴性。